HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce.※Main Feature:
— Double Combustion Chamber
— Double Italy Burner
–Burning Rate: 10-100kgs per hour
–Combustion Chamber: 0.1M3-1.2M3
— Mobile Incinerator, Standard shipping containers, Easy to move/transport system
— Free Installation, Pre-installed incinerator, Ideal for camps
— Ultraviolet lamp sterilization inside
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm Chimney 3Meter 3Meter 5Meter 5Meter 10Meter Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm Equipment Double chamber medical infectious waste incinerator Capacity 10-30 kg per hour Characteristics of waste
Mainly syringes and needles from immunization routine and campaign activities. However, the following average characteristics are considered*:
heating value above 2000 kcal/kg (8370 kJ/kg); content of combustible matter above 60%; content of non combustible solids below 5%; content of
non-combustible fines below 20%; moisture content below 30% by weight
Combustion performance: The medica waste incinerator shall be capable of reducing waste to ash not exceeding 10% of the total combustible
charges.
Outdoor installation. The medical waste incinerator will be installed outdoors. All incinerator components shall be suitable for but not
limited to outdoor shaded installation, including electric motors, be resistent to corrosion, moisture and related weather elements.Materials of construction: The incinerator shall not have any asbestos, asbestos-containing substances, mercury thermometers, and mercury
switches. Refractory materials shall be able to meet relevant standards under ISO TC33 and CEN/TC 187.Types of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air FiltersNanjing Clover Medical Technology Co.,Ltd.
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Jan, 2026
an industrial sized incinerator for tobacco and tobacco waste
inciner8ter model TS50 OR TS100 With delevery in Europe stare Croatia.Please can you send me the offer for pet crematory equipment.details of Chemical waste incinerator.
For animals to 90 kg. cremation equipment for pets ( Max. Size dogs till 80 kg )1. technical specification is for burner only
2what is the capacity of burner in one hour?
3. 35 for burners, 8 for control case, 1 for HD is that the weight of each item?
4. are these already configured so that the assembling becomes easy between control case and burners with HD?oil burner, 2sets (bigger capacity)
Temperature Thermocouple, 2 sets
Oil Tank 100Liters, 1 set
Thermal Gasket, 10 Meters
Incinerator control Case, 1 set
Blower, 1 set.an industrial sized incinerator for tobacco and tobacco waste. Details
Brand = Any
Model = Any
400v/50hz
· Types of waste – woods, tree branches, tree leaves, wood powder and card boards
· Daily Hours of operation = 7 hours
· Per day produce waste capacity = 10000kg
THEE SETS OF CATALOGUE ORIGINAL SHOULD BE RECIVED BY DHL + CD VEDIO
THREE YEARS GUARANTEE FREE FREOM DELIVARY DATE AND FREE SPAR PART ALSO, GARANTEE LATTER SPAR PART SHOULD BE VALID FOR 10 YEARS FROM THE DATE OF DELIVEARY .
ELECTRIC UNIT SHOULD BE DELIVERD WITH SERVIC MANUAL IN ENGLISH FOR EACH ONE
ELECTRIC SHOULD BE 380-220 V HZ 60 FOR ALL EQUIPMENTS
DELIVER TIME ASB
OFFER VALIDITY SHOULD BE 6 MONTHS
IN CASE OF ORDER I NEED
TWO SETS OF CERTIFICATE OF ORGINE SHOULD BE STAMPED IT FROM SAUDIA EMBASSY IN YOUR COUNTRY
COMMERCAL INVOICE( LEGALIZED FRO CHAMPER OF COMMERCE)
TWO ORGINAL BILL OF LADIN
should BE SEND SOME ONE FOR FIXE AND TRANING FOR 5 PERSON IN EACH LOCATION
SHOULD BE SEND YOUR DIZIN FOR INSTALATION UNITS
AWITING YOUR GOOD REPLY
Jan, 2026
A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE
SPECIFICATIONS OF A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE
1. Capacity of destruction in weight: 500 kg/h.
2. It should be able to operate not less than 8 hours/day
3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
4. Design Specification : Types A, B, C, D, and E of medical waste
5. “PYROLYTIC” combustion, by controlling the gasification of waste.
6. The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.
7. It should be able to reduce the volume of wastes by 98%.
8. It should be able to hold emission in the second burn with gas residence of not less than 2
seconds.
9. The incineration should be completely free from visible smoke as well as offensive odours.
10. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
• The Temperatures of combustion: Minimum will be 850oC and max 1400oC
• Post combustion: >1100oC.
11. The Internal diameter of the Chimney: Ø 400 and its height: 8 m
12. The Volume of the combustion chamber: 1.200 L
13. The Dimension of the door for loading in cm: 120×120.
14. Burner operation should be Automatic On/Off
15. Fuel : diesel/Gas
16. The supplier must provide necessary information for the best of the installation This incinerator with “PYROLYTIC” combustion must have:
17. A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch
Load
* A burner of lighting which the use is limited to the ignition of waste.
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on
the outside sheet metal.
* Composition of the refractory;
• Refractory concrete :
▪ . Thickness : ≥100 mm
▪ . Nature: 42% of Al203
• Insulate in fibrous panels :
▪ . Thickness: ≥75 mm
• Nature: Calcium silicate.
* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.
18. A chamber of post combustion of gases
* A burner of combustion of gases,
* A device of injection of air allowing a total recombustion of gases,
* A device of air inlet of cooling of waste gases,
* A sheath of evacuation of the gases burnt.
* Carcass in strong sheet steel with support of connection.
* Composition of the refractory;
• Refractory concrete :
▪ Thickness : ≥150 mm
▪ Nature: 65% of Al203
• Insulate in fibrous panel :
▪ Thickness: ≥85 mm
▪ Nature: Calcium
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* A secondary injection of air to ensure perfect oxygen content.
19. A control box ensuring the complete cycle of combustion.
20. A Pollution control device connected to the flue chimney must be connected to prevent
unnecessary escape of pollutants
21. Fan:
* Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
22. Controls and regulations:
Control box watertight to dust, including:
* A switch circuit breaker for each engine (ventilators and burners).
* A timer with adjustable temporization for the regulation of each burner.
* A regulator with digital watching for the temperature of combustion.
* A regulator with digital watching for the temperature of post combustion.
* Electric box.
21. The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing.
22. Process Filtering system : Scruber to be mentionned as optional
23. Emission Standards Compliance: BS 3316 or équivalent standard
23. Capacity to treat Plastic: Not less than 40% by weight
24. CE Manufacturing Compliance: BS EN 746-2-1997
23. The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
24. The installed incinerator must bear a one year guarantee.
25. The supplier shall perform an onsite installation of the incinerator.
25. The technical training of operators will have to be provided and given by a technician from the factory; it will consist of curative and preventive maintenance, and the use of machine, etc
NB.: Civil works and any other related services for the installation and training of operators must be included in the incinerator’s price.
Jan, 2026
containerised Hospital waste incinerator
One 40′ Standard – containerised Incinerator, and understand you can help us with the procurement of the same.Waste type or application : General and Medicine
Capacity kgs / hour : 75 to 350
Hospital and Laboratory equipment. .
One of our valued customer is interested to purchase a Hospital Waste incinerator as per following specifications:
Hospital waste incinerator
Capacity: 50 Kg / Hour
Brand new complete working unit
Burners: Dual fired (Gas and diesel)
20ft container with an incinerator plant for burning solid waste including the following main items:
1. INCINERATOR
2. SPARK ARRESTER
3. FLUE GAS STACK / EXHAUST PIPE
4. DIESEL OIL DAYTANK 400 L NET
5. INTEGRATED FIRE FIGHTING SYSTEM
6. INSTRUCTION MANUALS
7. SPARE PARTS FOR 1 YEARS OPERATION
medical waste incinerator is from 2.5 to 3 cubic meters and it’s capacity is from 60 t0 100kg per hour.
Jan, 2026
small hospital waste incinetor
WASTE INCINERATOR
– 150 KG/HR
– Compliant with EU rules, Directive 2000/76/EC
– Fuel type: Diesel
– Easy management and maintenance
– Temperatures:
850 deg C for municipal waste
1000 deg C for medical waste
1100 deg C for dangerous waste containing halogenated organic substances with content of chlorine or its compounds.a incinerator with an avarage burning capacity of 20-30kgs per hour and it should diesel or used motor oil, MEDICAL INCINERATORS, CAP: 3 TONS.producer of small hospital waste incinetor – for our clients (hospitals)
Jan, 2026
clover medcial yz model incinerator video
Jan, 2026
factory installed Diesel Fired Incinerator
Estimados, agradecería una cotización por los hornos crematorios para mascotas modelo YD-30 / YD-50.Mobile Diesel Fired Incinerator model
supplied with the following specifications:
complete with constant ventilation fans for extraction,
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.
Fully containerised mobile waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model plan to build a incinerator plant with 3 units of incinerators at the capacity of 500kg per hour each.
Together with other facilities like operation office, store, space to clean waste containers and 3-4 worker living quarters.
Necesito saber
1.ficha tecnida
2.guía mecanica
3.elevaciones
4. Los quemadores son Ecologicos.?? 5.’caracteristicas generales
Del YD 50 and. YD 100 Long Life pet crematory
in Diesel ….Me interesa este producto Long Life Pet Crematory (YD-50), y quiero conocer más detalles sobre:
Dame la lista de precios exactos por favor.
Me gustaría pedir algunas muestras. ¿Podría enviarme la lista de precios de muestras?Raw Medical Waste Incinerators. Can you please provide an official cost quote for purchase of (2) incinerators, whichever model has a comparable Capacity = 30 kg/hr.
Jan, 2026
Incinerator capacity of destruction of 350 kg/hour
average daily slaughter is about 120 pigs. The Condemned material and byproducts from the abattoir for disposal is around 1000 kgs.daily
one line incinerator for the destruction of hazardous medical waste.
– Incinerator capacity of destruction of 350 kg/hour, calorific value of waste will be 13-25 MJ/kg
[3,500 kcal/kg] and maximum heat capacity 1,225,000 kcal/hr.
– Incinerator destruction capacity will be 8.4 tons/day and operation time will be 24 hr./day.
– Waste will be through automatic feeding system into the incinerator.
-The temperature will modulated in varying flow and percentage in oxygen, combustion gas is re-burned
in the re-combustion[secondary] chamber at a temperature of minimum 1,100 C during 2 seconds.
– Control panel will be fitted with a functional synoptic view showing the operating situation of the whole
incinerator and controlled by DCS/PLC system.
– Gas treatment system will respect the EE standard [Directive 2000/76/EC-4/12/2000.
– TOC of slag and bottom ashes will be less 3% of the dry weight.
– Installation will be completely free from visible smoke.
– Incinerator will be designed as a Packaged unit, having electrical connection pre-wired and final pipes
in place.
– Incinerator will have automatic de-ashing system with upward direction.
– Incinerator will have flue gas treatment system inclusive [emergency by-pass stack, gas cooling system,
two reactors and particulates filtering system] and guarantee of emissions out of incinerator.
– Training of AKU staffs at site.
– Site may be inspected and examine existing ATI machine, capacity 150 kg/hr.in 24 hour operation.
– Existing infrastructure space is available in basement, 100’ Length x 30’ wide x 20’ Height for 2nd Incinerator.
– Existing chimney length is 12 meter, and width is 24”dia.
Jan, 2026
small scale incinerator of burning capacity
Poultry Incinerator – 400 kgs feed per day.a small scale incinerator of burning capacity 30kg/hr=1No. Note that it should be portable as this is meant for oil fields work on tented camps. Also it has to be diesel operated as our location is remote. 150!kg per hour LPG smokeless incinerator to be used at the international airport. This is a requirement bu the bio security that all international flights need all rubbish burnt within a set time.Required load capacity is 150Kg
Chamber – Primar 900 liters Secondary: 300Litres
Chimney 8M
Burning Rate: 50kgs/hr Yes
Feed Capacity: 150kgs Yes
Primary Combustion Chamber: 900 litres Yes
Secondary Combustion Chamber: 300 litres Yes
Mix Combustion Chamber: Yes Yes
Smoke Filter Chamber: Yes Yes
Feed Mode: Manual Yes
Power: 0.7Kw Yes
Fuel Type: Diesel Oil/ Natural Gas/LPG Yes. Different Price if oil or gas fuel.
Internal Dimensions: 120 x 90 x 85cm (primary chamber) Yes
External Dimensions: 200 x 160 x 310cm (without chimney) Yes
Burning Efficiency: >98% Yes
Jan, 2026
ecologically friendly incinerator
50 bed hospital and would like to have your recommendation for incinerator that can effectively handle the load of 50 bed hospital.Incinerator for burnable garbage (paper & organic) medium capacity (100/150 lts). Bio Medical Waste Incinerators,
Capacity: 50kgs per hour Medical Waste Incinerator Model TS50 ( PLC ) with both option on Fuel ( Natural Gas and / or Diesel2 Burners
2 Temperature Thermocouple
5 meters for thermal gasket
1 incinerator control case
1 Blower ecologically friendly incinerator for burning polyproplylene bags we have 10 tons weekly