Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-06-27
2020-06-27
General specifications of a 100 kg/hr incinerator | |||
No. | Description | Parameter value | |
model | HICLOVER YD100 | ||
1 | Machine working mode | Oil + Power | Oil + Power |
2 | Voltage | 220V C 3 phase or 1 phase | 220V 1P |
3 | Oil consumption (lit/hr) | Average 25-32 lit/hr/chamber | Average 33Liters/hour/total incinerator 3 burners |
6 | Incineration rate | 100 kg/hr = 400-600 kg/8hr | average 100kgs per hour |
7 | Feed mode | Manual | manual |
8 | Primary combustion rate | 1000 lit | 1080 liters |
9 | Secondary combustion rate | 240 lit | 207 Liters |
10 | Tertiary combustion rate | 416 lit | 452 liters |
11 | Combustion chamber material | High temp. resistant concrete | High temp. resistant concrete |
12 | Internal dimensions (1st chamber) | 100*100*100 cm (l*w*h) = 1000 lit | 120*100*90cm(l*w*h) = 1080 lit |
13 | Internal dimensions (2nd chamber) | 40*40*150 cm = 240 lit | Diameter 42*150cm=207 Liters |
14 | Internal dimensions (3rd chamber) | 40*40*260 cm = 416 lit | Diameter 60*160cm=452 Liters |
15 | External dimensions | 300*155*200 cm (l*w*h) | 220*160*370 cm (l*w*h) |
16 | Door opening | 90*90 cm | 90*90 cm |
17 | Additional air fan | 1 fan (on the door) | 1 fan (on the door) |
18 | Fuel type | Diesel oil/ | Diesel oil |
19 | Burner | Brand: Radiator or Hofmat | Italy Baltur |
20 | Chimney length | 3-4 meters | 5 Meters |
21 | Chimney type and material | H-type stainless steel, or High temp. resistant concrete | 1 Meter High temp. resistant concrete +4 Meter Stainless steel |
22 | Smoke and smell filter | Yes, two stages. | Dry Scrubber 2 stages |
23 | Temperature monitor | Yes, (for 1st and 3rd chambers) | Yes, (all 3 chambers) |
24 | Temperature control | Optional | yes |
25 | Oil tank | 500 lit needed. | yes |
26 | Burning efficiency | >98% | yes |
27 | 1st chamber temperature | 300-700 oC | 800-1000 oC |
28 | 2nd chamber temperature | 500-1000 oC | 1000-1200 oC |
29 | 3rd chamber temperature | 800-1200 oC | 1000-1300 oC |
30 | Smoke residency time | >2 sec. | >2 sec. |
31 | Gross weight | 5-8 tons | average 6.5 Ton |
32 | No. of Burners | 3 | 3 |
2020-06-27
Items/Model
TS250( PLC)
Photo
Concept
Waste Incineration Therapy
Burn Rate
Average 250 kg/hour
Feed Ability
Standard 400kg/feeding
Control Setting
PLC( Programmable Reasoning Controller Burner)
Combustion Chamber
2000L
Inner Measurements
210x88x110cm
Second Chamber
1000L
Smoke Filter Chamber
Yes
Feed Setting
Guidebook
Voltage
220V
Power
2.0 Kw
Oil Intake (kg/hour)
Typical 24.2( DO)
Gas Intake (m3/hour)
***
Temperature Display
Digital Present
Temperature Level Security
Yes
Oil Tank
1000L
Feed Door
2.04 x 1.06 M
Smokeshaft
3Meter
Chimney Kind
Stainless-steel
1st. Chamber Temperature
800 ℃–– -1000 ℃
second. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
9000kg
External Measurements
3.00 mx1.60 mx3.00 m (without chimney)
TWO (2) YEAR UPKEEP SPARES PLAN FOR LINE ITEM 2 X OIL DISCHARGED HEATER
2 X CEMENT FIXING PACKAGE (25KG)
2 X THERMOCOUPLE
2 X FIRE ROPE (1M)
2 X HT MASTIC (PER INCINERATOR)
1 X PPE PACKAGE
2020-06-27
Design
YD-150
Photo
Burning Price
Typical 150 kgs/hour
Feed Capability
Standard 300 kgs/feeding
Key Burning Chamber
1500 Liters
Additional Burning Chamber
500 Litres
Mix Burning Chamber
Yes
Smoke Filter Chamber
Damp Scrubber System( 3 Area Type)
Feed Setting
Manual
Voltage
380V
Power
9.0 Kw
Fuel Kind
Diesel Oil/ All-natural Gas/LPG
Burner
Italy Original
Oil Consumption (Diesel Oil)
Average 24 kg/hour
Gas Intake (Gas)
***
Inner Dimensions
150 x 100 x 96cm (primary chamber)
Exterior Dimensions
240 x 170 x 380cm( without chimney/wet scrubber)
Temperature Monitor
Yes
Oil Tank Capacity( if oil fuel)
300 Liters
Door Opening
59 x 81cm
Chimney Length
10.0 Meters
Chimney Kind
Stainless Steel
Equipment Gross Weight
11000 kgs
Procedure Technical Specs
Main Chamber Temperature Level
800 ℃–– -1000 ℃
Second Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Burning Efficiency
> 98%
Waste Lower Calorific Power
3000Kcal
2020-06-27
![]()
Design
CA-200
Picture
Burning Rate
Typical 100 kgs/hour
Main Combustion Chamber
2000 Liters
Second Burning Chimney
Yes
Feed Setting
Manual
Voltage
220V
Power
3.0 Kw
Gas Kind
Diesel Oil
Burner
Italy Original
Oil Usage (Diesel Oil)
Average 53 kg/hour
Interior Measurements
200 x 100 x 100cm (main chamber)
Outside Measurements
290 x 200 x 170cm (key chamber)
Temperature Level Screen
Yes
Oil Tank Ability( if oil gas)
500 Liters
Door Opening
90 x 90cm
Smokeshaft Size
5.0 Meters
Chimney Kind
Stainless Steel
Tools Gross Weight
9000 kgs( with container)
Operation Technical Specifications
Paimary Chamber Temperature
800 ℃–– 1000 ℃
Additional Chamber Temperature
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Burning Effectiveness
> 98%
Waste Lower Calorific Power
3000Kcal
2020-06-27
Model |
A600, crematorium makers |
|||
Inner Measurements |
130 x 70 x 65cm |
|||
Suit for Animal |
Pet cat – – yes |
– Pet dog – yes |
Pig – no |
Cow – – no |
Key Item List |
Primary Combustion Chamber |
|||
Additional Burning Chamber |
||||
Mix-Combustion Chamber |
||||
Smoke Filter Chamber |
||||
Incinerator Control Situation |
||||
Chimney:5.0 Meters *( upgrade to Stainless Steel, free price) |
||||
Italy oil/gas heater: 02 units |
||||
Oil Storage Tank (if oil gas): 200Liters |
Design |
A600 |
Photo |
|
Feed Capability |
Ordinary 30 kgs per feeding( animal) |
Burning Rate |
Typical 15 kgs per hour( animal) |
Voltage |
220V |
Power |
0.59 Kw |
Gas |
Gas or Diesel oil or LPG Gas |
Burner |
Italy Heater |
Feed Setting |
Handbook Feeding |
Fuel usage (Oil) |
10.0-16.0 Kgs/Hour |
Gas usage (Gas) |
10.0-15.0 m3/Hour |
Exterior Dimensions |
175 x 100 x 180cm (main body) |
Internal Dimensions |
130 x 70 x 65cm( Primary Chamber) |
Waste combustion chamber |
600Liters |
Post Burning Chamber |
200Liters |
Oil Container Capacity |
200 Litres or More( Optional) |
Door Opening |
50 x 60cm |
Chimney |
5.0 M or Even More( Optional) |
Gross Weight |
3300kgs |
Chamber Product |
Refractory Concrete |
Max. Warm Value |
160,000 Kcal/Hr. |
Operation Technical Specs |
|
Solid Chamber temperature |
8000C -10000 C |
Concentration camp temperature |
10000C -12000 C |
Chamber Anti-Rate
|
14500C |
Residency time
|
2.0 Sec. |
Burning performance |
> 97% |
Waste Lower Calorific Power |
3000Kcal |
2020-06-27
BURNING RATE: -100 -150 kgs per hour
MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING)
MAX OPERATING TEMPERATURE LEVEL: 1000-1200 oC (AFTER HEATER BURNING)
SECONDARY MELTING CAPABILITY: COMPULSORY
DENSITY INSULATION: 50 mm high
Refractory capability: minutes 114mm
STURDY REFRACTING LINING TO WITHSATND 17500C
AVEARGE BURN OUT TIME: MAXIMUM 3HRS
GAS TYPE: FUEL OIL (DIESEL)
FUEL INTAKE IN LTRS/HR: average 14
RESIDNECY TIME IN SECONDARY CHAMBER: 2 PHASES
Items/Model
TS150( PLC)
Photo
Concept
Waste Incineration Treatment
Burn Price
Standard 100-150 kg/hour
Feed Capability
Standard 750kg/feeding
Control Setting
PLC( Programmable Reasoning Controller Incinerator)
Chamber Material
High Alumina Fire Brick Wall, 1750 ℃ Rate
Paint for outdoors face
800 ° C Price
Burning Chamber
1570L
Inner Dimensions
150x100x105cm
Secondary Chamber
750L
Smoke Filter Chamber
Yes
Feed Mode
Guidebook
Voltage
210/230V 50/60Hz
Power
0.9 Kw
Oil Consumption (Liter/hour)
Ordinary 14( D.O)
Gas Intake (m3/hour)
***
Temperature Screen
Digital Show
Temperature Level Defense
Yes
Oil Tank
2000L
Feed Door
80x60cm
Chimney
10Meter
Smokeshaft Kind
Stainless Steel
1st. Chamber Temperature
800 ℃–– -1000 ℃
second. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
8500kg
Exterior Dimensions
300x160x280cm( without chimney)
2020-06-28
Version
YD-30 Mobile Type
Photo
![]()
Burning Rate
Average 30 kgs/hour
Feed Ability
Typical 60 kgs/feeding
Chamber Text
Stainless Steel
Mobile Feature
With Wheel and also Brake
Primary Burning Chamber
280 Liters
Secondary Combustion Chamber
150 Litres
Mix Burning Chamber
Yes
Feed Setting
Handbook
Voltage
220V
Power
1.5 Kw
Gas Kind
Diesel Oil
Burner
Italy Original
Oil Intake (Diesel Oil)
Standard 13.3 kg/hour
Inner Dimensions
80 x 60 x 60cm (main chamber)
Exterior Dimensions
125 x 90 x 260cm (without smokeshaft)
Temperature Level Display
Yes
Oil Container Capacity( if oil fuel)
100 Litres
Door Opening
50 x 50cm
Smokeshaft Size
2.0 Meters
Chimney Type
Stainless-steel
Equipment Gross Weight
1600 kgs
Operation Technical Specifications
Key Chamber Temperature
800 ℃–– -1000 ℃
Secondary Chamber Temperature
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Burning Effectiveness
> 98%
Waste Lower Calorific Power
3000Kcal
2020-06-28
Version |
A1500 |
|||||
Inner Measurements |
150 x 100 x 96cm |
|||||
Suit for Animal |
Pet cat – – yes |
– Dog – yes |
Pig – small |
Cow – – tiny |
||
Main Product Listing |
Main Burning Chamber |
|||||
Additional Burning Chamber |
||||||
Mix-Combustion Chamber |
||||||
Smoke Filter Chamber |
||||||
Burner Control Case |
||||||
Chimney:10.0 Meters *( upgrade to Stainless-steel, cost-free price) |
||||||
Italy oil/gas heater: 03 sets |
||||||
Oil Tank (if oil fuel): 500Liters |
||||||
Design for Pet Dogs Cremation Business |
Movable system & & Auto. Door & Fire/Flame Monitoring Opening |
|
||||
Independent Placement for Tiny Pet Dog |
|
2020-06-28
Product |
Requirements |
Design |
YD-30C |
Key Product Listing |
Main Combustion Chamber( Main body stainless-steel) |
Secondary Burning Chamber( Main body stainless steel) |
|
Mix-Combustion Chamber |
|
Wet Scrubber( Laundering Tower)( Text stainless-steel) |
|
Burner Control Situation |
|
Chimney:5.0 Meters *( upgrade to Stainless-steel, complimentary cost) |
|
Italy burner: 02 collections |
|
Oil Storage Tank (if oil gas): 100Liters |
Automatic PLC controller incinerator plant with Twin warm burners and twin chamber. Burning capacity up to 30 Kg per hour. Water showering cyclone air cleaner Discoloration less steel 304 quality sheet for water scrub chamber Time up to 250 mints. Totally automatic electric control circuit with timers Key temperature level 800-1000 deg C Second temperature1000-1200 deg C Hands-on filling/ dumping Automatic start at power fall short during procedure Fast temperature level increase control automated identifies quick shedding materials and save heater gas consumption by turn off/ on burner automatically. Appropriate for waste of health centers Variety of burner 2 Nos Voltage 380V 50Hz Functional enjoinment 5 C 60 C Moisture 10 C 90%
Gas kind Natural gas Variety of chamber 02 Nos
2020-06-28