HICLOVER Waste Burner Front view


— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.

— — Single combustion chamber, double burning chambers, three burning chambers as well as multi-combustion chambers waste incinerators.

— — System remedies for clinical waste environmental.

— — High shed price, from 5kgs to 1000kgs per hour.— — New Design for pet dog animal cremation company.

— — HICLOVER, relied on partner with years of experience.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Nanjing Clover Medical Innovation Co., Ltd.

Tel: +86 -25 -8461 0201 Internet site: www.hiclover.com Email: [email   shielded] Email: [e-mail   protected]


Burner manufacturing facility


Key Features:

— — Complete variety burner with Saved money Tiny Range incinerator, Criterion Small-Large Scale incinerator,

General Municipal Solid Waste Incinerator, Pet and Animal Cremation, 

Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
— Single combustion chamber, double combustion chambers, three combustion chambers and 
multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.

— HICLOVER, trusted partner with years of experience.

WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel: +86 -25 -8461 0201

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Burning Capability – – 400 kg/time and also must not be much less than 300 kg/time. Optimum combustion time must be 6 times/dayChimney outside size – – 300 to 400 mmFan power – – Must not exceed 1.1 kwVoltage – – 220VOil consumption – – Should not go beyond 14kg/hFeeding door angled measurement ( mm) – – Not much less than 500mmIncineration Temperature. ( ⁰ C) – – 800 or aboveCO – – Need to not surpass 100 mg/m3SO2 – – Must not exceed 400 mg/m3HF – – (Hydrogen fluoride) Need to not exceed 9.0 mg/m3NO2 – – Should not go beyond 500 mg/m3Smoke dust – – Should not go beyond 100 mg/m3Height of the Burner – – Not much less than 10m over ground levelManufacturer’s Warranty – – Not much less than 1 yearElectrical Link – – From nearest distribution box utilizing 25mm2 electrical cable television as well as all related links and wiring


HICLOVER Made Waste Incinerators


HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We supply single burning chamber, double burning chambers, 3 combustion chambers and also multi-combustion chambers waste incinerators for lab, clinic, healthcare facility, clinical center, hygiene scientific waste damage with clinical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, and so on.

Our variety of burners cater for tiny to huge range pet cremation associated companies, such as fowl ranches, livestock farms, sheep ranches, pig farms, stables, kennels, screening lab, catteries, pet crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.


Pet Dog Animal Crematory Incineration


Incineration is the most obvious solution for total destruction of municipal waste, avoiding 

all the direct and indirect risks associated with other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the 
same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level.

※ Main Feature:–– 3 Burning Chambers or A/B Main Burning Chamber— — Dual or Three Italy Heater–– Burning Rate: 80-800kgs per hour–– Burning Chamber: 1.0M3-10.0 M3 ※ Optional Function/Parts/Material/ Burning Price: — — Stainless Steel Smokeshaft — — Dry Smoke Filter Chamber— — Smokeshaft Elevation Customized Made— — Semi-Automatic Waste Feeding— — 3-Section Damp Scrubber System— — Movable Platform Feeding Door— — Added Burner

— Upgrade/Downgrade Burning Rate
WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel: +86 -25 -8461 0201

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

System purpose Infected clinical waste decontaminationUnit made from stainless steel NecessaryDecontamination process is performed in a shut system NecessaryWaste shredding within sterilization process NecessaryDecontamination technique 1No pressure; 2Moisture and also heat.Microbiological purification degree At least 6 log10Sterilization cycle temperature At the very least 1400CThe sanitation cycle time Not a lot more than 40 min.One cycle treated waste volume At the very least 100 litrųOne cycle cured waste weight At least 7 kgDecontaminated waste has to be 1Dry,2 Odorless,3 Not identifiableThe waste quantity reduction after treatment At least 70% The waste weight reduction after therapy At the very least 30 % System control MicroprocessorControl panel Digital with touch screenNoise level At least 80 dBPower consumption Not extra than 0,5 kWh/kgWater consumption Not more than 0,003 m3/kgFiltering system 1At least two-stage carbon filters; 2HEPA filter.HEPA performance At least 95% Device ability At the very least 15 kg/hr. Impact on the environment and employees Safe, environmentally friendlyDimensions ( for specific space) 90 size ( ± 10 ) x 150 deepness ( ± 10 ) x120 elevation ( ± 10)


HICLOVER INCINERATORS


Medical waste is posturing a growing problem all over the world, jeopardizing the wellness of staff, individuals, disposal employees and anybody else entering contact with the often dangerous materials discarded by hospitals and other health care sites. Hospital waste varies from website to site and also the most significant difficulty is to dispose of this variety of waste streams. Incineration is still the favored way to process medical waste without threatening the health clients, staff or any individual else coming into contact with them. Professional waste is costing an increasing number of to take care of securely. Health Clinics and also University hospital can currently handle their very own waste streams using among our expert clinical incinerators. Ruining contaminated materials at source is without a doubt the most efficient as well as efficient method of taking care of waste that could possibly spread viruses or conditions.

Average 20% -25% of the complete waste produced by healthcare facilities is considered as harmful and may develop a variety of health and ecological threats otherwise handled and also destroyed in a proper fashion.

With years worth of experience in this field, our medical variety of burners are designed to provide for the affordable requirements of small clinics to the more requiring and specialized requirements of big hospitals in their waste administration processes.

HICLOVER is now providing a complete series of medical waste burners, made to give efficient waste destruction, using finest readily available technologies and also environmentally friendly process. As a result of the secondary chamber with its 2 second retention period, our clinical burner range is well matched to process clinical waste.

Our products ensure effective, tidy as well as problem-free disposal of medical waste is possible. The incineration of professional waste including pathological waste (red bag waste), Biohazards & & Sharps, General Medical Waste, from Health Centers, Proving Ground, Drug Firms, Drug Produces, Medical Care Trusts, Plastic Surgery Centers, Nursing Houses, Treatment Houses and also various other Scientific Waste.

○ Middle-Small Ability( TS Model)

※ Main Qualities:

— — Double Burning Chamber

— Dual Italy Heater

–– Burning Price: 10-100kgs per hr

–– Combustion Chamber: 0.1M3-1.2 M3

※ Optional Function/Parts/Material/ Burning Price:

— — Stainless-steel Smokeshaft

— Dry Smoke Filter Chamber

— — Chimney Height Customized Made

— Upgrade/Downgrade Burning Rate

○ Large-Middle Capacity( YD Version)

※ Highlight:

–– 3 Combustion Chambers

— — Dual Italy Heater

–– Burning Price: 30-600kgs per hour

–– Combustion Chamber: 0.36M3-5.5 M3

※ Optional Function/Parts/Material/ Burning Price:

— — Stainless Steel Chimney

— — Dry Smoke Filter Chamber

— — Smokeshaft Height Custom Made

— — Semi-Automatic Waste Feeding

— — 3-Section Damp Scrubber System

— — Movable System Feeding Door

— — Added Heater

— — Upgrade/Downgrade Burning Price

 


incinerator Model TS150


HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses.

WWW.HICLOVER.COM|Waste Incinerators

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]    


Incinerators QA


Q: what is kind of waste can use in this equipment?
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any 

explosive and radiation material, liquid waste and gas waste.

Q: The Residency time in second burning chamber

Tel: +86 -25 -8461 0201

not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.  

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, 

there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion 
time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. 

When incinerator use in hospital, please calculate the waste output capacity around 2kgs 
per people per day. If there are 200 sickbed in the hospital, that’s mean you need one 
incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs 
per hour. According the operation time per day, waste material, budget, 
development, etc, you can use capacity from 30-50 kgs per hour incinerator.
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.

Q: Assembly and Testing
A: We supply all documents and incinerators easy to installation and operation. Customer 

can send people come to our factory to learn installation and operation. Generally, 
We do not send engineer to local site if not request. The dispatch cost is extra according to order.

Q: Combustion Temperature
A: The first combustion chamber: 800-1000 centi degree.
The second combustion chamber: 1000-1200 centi degree.

Q: Incinerator Control Mode
A: Default Control mode is common control case. PLC mode according to model and order.

Q: Operation and maintenance costs
A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000usd per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician 

knowledge to operate/inspect/maintaince incinerator/burner/blower according to 
operation user guider, and know risk of medical waste to protect worker self with necessary protection element.

Q: The Residency time in secondary combustion chamber

A: 02 sec.
WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm


medical waste products burner


an incinerator suitable for chemcial waste containers. ability concerning 100 kgs per hr with a scrubber.1- One system of

medical waste materials incinerator
– – Ability: 100 kg–– Gas: gas oil

2 -One system of typical waste products burner – Capability: 150 kg
–– Fuel: gas oil this type of capability will be a waste burning central for a tiny city. you can locate various other

firm. our items primary for small waste output. for hospital straight, neighborhood at hospital, or portable/mobile

burner to one site when end-customer demand. incinerator without smoke and smelting for the setting.

capapcity 500kg per day. Could you define the factor of oil gas? By this you indicate gasoline or diesel?
with dieseil burner.we managed to get a walk in Algeria, and also we intend to export to other nations in Africa.
we define that we have an interest in mobile burners for medical facility usage.


an incinerator for our dental clinics


a burner for our oral clinics.The burner need to follow” Technical Standard NTON 05-015-02 Monitoring as well as Solid Waste Disposal Hazardous carbon monoxide go “, in addition to meeting worldwide requirements capability requirements for new fixed resources and discharges from the Epa United States (Epa EPA) Incinerators Medical and also Medical facility contagious waste (HMIWI its phrase in English) and also the standards of the Globe Health And Wellness Organization (THAT ).

According to direct 8.5.1.3 of the NTON 05-015-02 incinerator have to have the following:

” Incinerators outfitted with a cam primary and a secondary combustion, equipped with heaters capable of achieving full burning of waste and prevalent devastation of harmful and hazardous chemicals (dioxins and furans among others), affixed to the strong waste bioinfectious.

a) primary combustion chamber, it requires a temperature of 800 ° C as well as one hr dwell to be damaged waste produced ash as well as gas, consisting of dioxins can create cancer is discovered.

b) In the secondary combustion chamber should get to temperature levels around 1,100 º C and also have to be operated with a residence time of the flue gases of a minimum of 2 secs. To deal with gas circulation as well as entrained particles, before being launched into the atmosphere, ought to be added towers chemical washing, cyclones, filters.”

The incinerator mounted must adhere to the layout to make sure the destruction of all hazardous, biological, industrial waste and others. Combustion” PYROLYTIC” permits control of the gasification of waste and also stay clear of substantial release of black smoke as well as fine powder throughout loading. It likewise allows, complete as well as routine combustion of the waste.

The primary advantages are a controlled combustion that assures the absence of smoke, dirt, shade or smell. It is also automated, so you do not require guidance and has a low gas usage.

The incinerator consists of:

1. A combustion chamber:
a. water tight door for hands-on loading of waste.
A heater start is limited to swelling of waste.

2.
a. heater combustion, low power.
b. A shot gadget air for total re- combustion of the gases.

c. An input gadget cooling air of the combustion gases.

3.

The burner fulfills as indicated on waste incineration.
They will not burn plastics, packaging other than that the quantity so little that gases require not obtain any kind of therapy, second burning chamber to 1100C deals with every little thing.

The smokeshaft is 350 mm inner size as well as an elevation of 8.13 m will certainly with hatch evaluation.

Combustion chamber

– The burning chamber is thick steel plate (3 to 10 mm) with reinforcements, specially constructed.
– Front loading with water tight door installed on joints, locking screw wheel, adaptable gasket as well as a shielding refractory lined.
– An interior cellular lining of refractory concrete consisting of 42% of H ² 03 (alumina) as well as 100 mm thick wall surfaces.
– fibrous insulation panels made of calcium silicate with a thickness of 75mm.
– Automatic Burner (diesel or gas must be specified in the order) with flames diving in one piece monoblock with a digital ignition system, long-term ventilation control shutoff and seclusion valve.

– burning floor made in carborundum, stopping binding of glass and slag.

Afterburner gases

– The afterburner is strong sheet steel flange link.
– Interior filling up refractory concrete with really high alumina material (65 % H ² 03) as well as a thickness of 150 mm.
– thermal insulation panels made of coarse silicates and calcium with a thickness of 85 mm.
– diesel or gas burner (must be specified in the order ), monobloc straight fire, electronic ignition, risk-free, permanent air flow, control valve as well as seclusion valve.
– air injection nozzles made of refractory steel with a circulation control shutoff.
– These nozzles are particularly designed as well as patented by ATI to guarantee really low hydrocarbon discharges.
– A secondary air injection is set up and also ensures ideal oxygen web content.
– Fan distribution secondary as well as primary air, the air flow regulation is effected through shutoffs and also actuators on automated cycle commands.

Control as well as law
Control board dustproof, painted sheet with baked paint making up:
– A circuit breaker button for each electric motor (followers as well as heaters).
– A timer flexible dead time for every heater control.
– A regulatory authority with an electronic screen for the combustion temperature level.
– A controller with electronic display screen for temperature afterburner.
– The electric panel meets existing standard. For elimination of ash, a squeegee steel frying pan with deals with

Paint
– Shade: Light + dark blue.
– Unique heat.

OPERATION

The operation thereof is as follows:

– Charging waste.
– Shut the door.
– Getting the combustion cycle throughout which no surveillance solution (duration 2 hrs) is called for.

The burning cycle automatically guarantees:
– Starting the secondary air follower.

After 10 mins, the afterburner is temperature:

– Switching on the automatic heater combustion chamber, which assures the result of the gasification of waste. The operating time of the burner is programmable according to the kind of waste, utilizing an adjustable mechanical timer from 1-60 minutes.
– Automatic start of combustion air follower.

After 2 hrs, the end of” burning cycle” instantly guarantee:

– The closure of key air servomotor.
– The post-combustion heater off.

During charging, opening the door instantly makes sure immediate shutdown follower additional as well as key air. At the end of the combustion cycle the follower primary/ second air and burner remains to run for 2 hours to safeguard the burners and to cool the stove. After this time the program instantly shuts off the installment totally.

GAS USE

This installment shall consider operation of diesel with the complying with qualities:

Thickness at 15 ° C (max/ min) 0.88/ 0.82 kg/ l.
Weight sulfur 0.2 % max.
Kinematic thickness at 40 ° c (min/ max) 2/ 4.5 mm2/ s.
Point above 55C swelling.
Cold filter connecting factor -10 ° C max.

DIESEL AND FOOD TANK BURNER

The gas storage tank will lie linked to the dugout roof covering incinerator in a bund as well as have the following characteristics:

– Ability: 1,200 litres.
– Constructed from sheet steel for simple wall surface installment cubeto.
– Outcome for ventilation diameter 1 1/2 “.
– Pressure gauge and also filler cap.
– Meter and level switch

The incinerator has an usage of 16.2 liters of diesel hr to shed waste produced operation 10 hours a week anticipated in 2 burning, so that autonomy will certainly be 7.5 weeks. The tank will certainly have an electrical outlet as well as an inlet for return. Pipelines for oil will certainly drive the black steel pipeline with longitudinal electric resistance welded 3/4″ DN 20mm size. In the tank outlet pipeline retainer particles filter, with light weight aluminum body is positioned, light weight aluminum cup and also stainless steel filter with openings 100 microns in diameter.advise on the intake rates, is that for both chambers, or per chamber?