HICLOVER Automatic Roll Air Filter Supporting Australia’s Mining and Quarry Operations

HICLOVER Automatic Roll Air Filter Supporting Australia’s Mining and Quarry Operations

Australia’s mining economy is defined by its scale and diversity. From iron ore operations in Western Australia to quarries in New South Wales and underground refuge stations in Queensland, each site relies on dependable ventilation and dust control. The HICLOVER Automatic Roll Air Filter has become an important part of this landscape, combining smart winding technology, PLC automation, and G3-grade prefiltration to meet local industry requirements.

Automatic Roll Air Filter for Australian Quarry Dust Collection Systems

Quarry operations are known for producing high levels of airborne particulate matter, especially at crushing, screening, and bulk storage areas. An automatic roll air filter for Australian quarry dust collection systems provides a practical solution by capturing coarse dust before it reaches critical HVAC or dust suppression systems. With a self-advancing roll design, the filter ensures consistent airflow even in environments where dust density fluctuates throughout the day. This reduces both equipment wear and maintenance interruptions.

Smart Winding Filter Unit for Australian Underground Refuge Stations

Safety is paramount in underground mining, where refuge chambers are installed to protect workers during emergencies. Air quality in these sealed environments depends on effective prefiltration. A smart winding filter unit for Australian underground refuge stations integrates photoelectric control and differential pressure monitoring, advancing fresh media automatically when filter resistance reaches the preset threshold. The rugged carbon steel or stainless-steel frame construction ensures long-term reliability, even under the demanding conditions of Australian hard-rock mines.

Ventilation Corridor Dust Filter for Australian Iron Ore Operations

The Pilbara’s vast iron ore mines depend on long ventilation corridors to supply clean air to conveyor tunnels and underground shafts. A ventilation corridor dust filter for Australian iron ore operations is designed to handle air volumes exceeding 25,000 m3/h, removing coarse particles that can otherwise overwhelm downstream systems. The modular design of HICLOVER filters allows multiple units to be combined, supporting the heavy airflow demands unique to Australian iron ore infrastructure.

Technical Advantages of HICLOVER Automatic Roll Air Filter

  • Filter Media: G3 synthetic fiber optimized for coarse dust capture in mining and quarry applications

  • Automation: PLC-based control with manual override and optional photoelectric detection

  • Drive System: 0.1 kW three-phase gear motor designed for continuous duty

  • Scalable Design: Modular assembly supports high air volume corridors and bulk facilities

  • Durability: Powder-coated carbon steel or stainless steel options withstand abrasive and corrosive environments

Why It Fits Australian Mining Conditions

The Australian mining and quarrying sector operates in remote, high-dust regions where maintenance access is limited. Automated filter systems like HICLOVER’s reduce the need for manual intervention, improve compliance with air quality regulations, and protect both equipment and personnel. By addressing the needs of quarries, refuge stations, and iron ore corridors, HICLOVER provides a targeted solution for an industry central to Australia’s economy.

Closing Perspective

From open-air quarries to deep underground mines, Australia’s resource industries demand reliable dust control technology. The HICLOVER Automatic Roll Air Filter delivers intelligent prefiltration, energy savings, and robust performance designed for the extremes of the Australian mining environment.


Contact Information
Mobile (WhatsApp): +86-13813931455
Website: www.cloverfilter.com
Email: [email protected]


Mobile: +86-13813931455(WhatsApp)

Website: www.cloverfilter.com

Email:     [email protected] 

 

2025-09-03/14:16:32

Containerized Mobile Burner Pre-assembled, containerized type

Version

CA100

Photo

Waste Therapy

Medical Waste Incineration Therapy

Feed Ability

Ordinary 100-200 kgs per feed

Burning Rate

Typical 100-120 kgs per hr

Burning Time per Feed

Standard 1-2 hr

Control Setting

PLC( Programmable Logic Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Fuel

Diesel oil

Burner

Italy Heater

Feed Mode

Handbook

Temperature Monitor

Digital Display

Fuel intake (Oil)

Typical 20.4 Kgs/Hour

Interior Measurements

100x80x70cm (Main Combustion Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste burning chamber

560Liters

Blog Post Burning Chamber

280Liters

Oil Tank Capacity

200 Litres

Door Opening

70 x 50cm

Chimney

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max. Warm Worth

166,000 Kcal/Hr.

Procedure Technical Specs

Solid Chamber temperature

8000C -10000 C

Concentration camp temperature

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning effectiveness

> 98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-20

Automatic Roll Air Filter Solutions for Australian Mining Facilities

HICLOVER Automatic Roll Air Filter Solutions for Australian Mining Facilities

Australia’s mining industry continues to expand in scale and technical complexity, with critical activities in nickel processing, heavy mining equipment maintenance, and mining truck workshops. Each of these environments generates dust and coarse particles that can compromise both air quality and equipment reliability. The HICLOVER Automatic Roll Air Filter has been engineered to address these challenges by providing automated, heavy-duty prefiltration systems that match the conditions found in Australian resource operations.

Heavy Duty Ventilation Prefilter for Australian Nickel Processing

Nickel processing plants in Western Australia demand ventilation prefilters capable of withstanding high dust concentrations from crushing, drying, and refining processes. A heavy duty ventilation prefilter for Australian nickel processing ensures that coarse particles are removed before they can clog downstream HEPA filters or damage sensitive refining equipment. By integrating G3-grade filter media and a PLC-controlled self-advancing roll mechanism, HICLOVER systems keep air corridors stable and energy efficient. Mining operators can explore more about these solutions at www.cloverfilter.com.

Automatic Roll Filter for Australian Mining Equipment Maintenance Bays

Maintenance bays for haul trucks, drills, and crushers are often exposed to dust, oil fumes, and airborne debris. Using an automatic roll filter for Australian mining equipment maintenance bays provides a continuous layer of protection for HVAC intakes and workshop ventilation ducts. The 100W three-phase gear motor drives the roll system to replace filter media automatically, maintaining steady airflow without requiring manual changes. This automation reduces downtime and ensures compliance with Australian workplace air quality standards, particularly in remote mining regions.

Automatic Ventilation Prefilter for Australian Mining Truck Workshops

Mining truck workshops, especially those supporting fleets in Queensland and the Northern Territory, face unique air quality issues. A automatic ventilation prefilter for Australian mining truck workshops captures coarse dust stirred up by constant heavy vehicle activity. The modular filter design allows multiple units to be connected, handling air volumes over 25,000 m3/h, ensuring that large-scale facilities remain within safe operating conditions. More technical specifications can be found via www.cloverfilter.com.

Technical Strengths of HICLOVER Filters

HICLOVER’s Automatic Roll Air Filter series incorporates several engineering features that align with Australian mining sector demands:

  • Synthetic Fiber Media (G3 Efficiency): Designed for coarse dust capture in mining and metallurgical environments.

  • PLC Control with Differential Pressure Sensors: Automatically advances filter media when resistance exceeds the pre-set limit.

  • Durable Construction: Carbon steel powder-coated frames or stainless-steel options for corrosive environments.

  • Low Energy Drive System: A compact 0.1 kW motor ensures reliability while minimizing energy usage.

  • Modular Scalability: Units can be expanded to suit the largest ventilation corridors found in mines and processing plants.

Why the Australian Mining Sector Chooses HICLOVER

Australian mining operators demand low-maintenance, automated solutions that can operate continuously in dusty and abrasive conditions. HICLOVER’s systems deliver reliability, reduce manual filter replacement requirements, and support compliance with national health and environmental standards. Their ability to adapt across nickel refineries, mining truck workshops, and equipment bays makes them an ideal partner for Australia’s resource industries.

Conclusion

With mining operations spread across remote and often harsh environments, Australia requires air filtration systems that combine automation, durability, and high airflow capacity. The HICLOVER Automatic Roll Air Filter provides a robust solution tailored to the needs of nickel processing plants, maintenance bays, and mining truck workshops, ensuring cleaner air, reduced operational costs, and greater system efficiency.


Contact Information
Mobile (WhatsApp): +86-13813931455
Website: www.cloverfilter.com
Email: [email protected]


Mobile: +86-13813931455(WhatsApp)

Website: www.cloverfilter.com

Email:     [email protected] 

 

2025-09-02/17:36:13

Automatic Roll Air Filter for Australia’s Mining and Metallurgical Facilities

HICLOVER Automatic Roll Air Filter for Australia’s Mining and Metallurgical Facilities

Australia is home to some of the world’s largest smelters, cement plants, lime processing facilities, and mining camps. These environments face significant dust and particulate challenges that directly impact equipment performance, worker health, and regulatory compliance. The HICLOVER Automatic Roll Air Filter is designed to provide continuous, automated prefiltration that meets the demands of Australian mining and metallurgical industries.

Automatic Roll Air Filter for Australian Smelters and Metallurgical Plants

In aluminium, nickel, and copper smelters, the air is often saturated with coarse particulates, abrasive dust, and corrosive fumes. Installing an automatic roll air filter for Australian smelters and metallurgical plants ensures continuous removal of airborne particles before they reach sensitive HVAC and dust control systems. With its PLC-controlled self-advancing filter media, the system minimizes downtime, while the G3-grade synthetic fiber captures large dust particles common in pyrometallurgical processes.

Roll Type HVAC Prefilter for Australian Cement and Lime Industry

Australia’s cement and lime industry is concentrated in regions like Queensland, New South Wales, and Victoria. Kilns, mills, and conveyor tunnels generate significant dust loads that can rapidly clog conventional filters. A roll type HVAC prefilter for the Australian cement and lime industry provides coarse dust capture with automatic filter media advancement, ensuring stable airflow and reduced pressure drop across large HVAC systems. This is particularly important in kiln intake corridors and bulk storage silos, where continuous operation is critical.

Industrial HVAC Prefiltration Unit for Australian Mining Accommodation Camps

Remote mining operations in Western Australia and the Northern Territory rely on accommodation camps where HVAC systems are essential for comfort and safety. Dust from surrounding mine sites can easily infiltrate air corridors, reducing air quality for workers. Installing an industrial HVAC prefiltration unit for Australian mining accommodation camps provides a first stage of protection, extending the life of fine filters and ensuring compliance with occupational health standards. The modular design of HICLOVER’s roll filters allows easy integration into existing HVAC corridors, even in large-scale camp facilities.

Technical Advantages of HICLOVER Automatic Roll Air Filter

  • Air Volume Handling: Up to 26,000 m3/h per unit, scalable through modular design.

  • Filter Media: G3 synthetic fiber rolls designed for coarse dust removal in heavy industry.

  • Motor Drive: Three-phase 100W gear motor ensures smooth and reliable media advancement.

  • PLC Control: Automated filter replacement triggered by differential pressure sensors with manual override available.

  • Frame Construction: Powder-coated carbon steel, aluminum alloy, or stainless steel for durability in corrosive and dusty environments.

  • Energy Efficiency: Stable airflow reduces blower energy consumption while extending filter lifespan.

Why HICLOVER in the Australian Mining Sector

  1. Tailored for Harsh Conditions C Engineered for environments with heavy dust, abrasive particles, and corrosive fumes.

  2. Remote Operation Ready C Automated systems reduce the need for frequent manual maintenance, vital in isolated mining regions.

  3. Regulatory Compliance C Supports Australian standards for air quality in mining, cement, and smelting industries.

  4. Versatility Across Industries C From smelters and cement kilns to mining camps and conveyor corridors, the system adapts to multiple applications.

Conclusion

The HICLOVER Automatic Roll Air Filter provides a reliable, automated, and cost-effective prefiltration solution for Australia’s smelters, cement and lime plants, and mining accommodation camps. By combining PLC-controlled automation, modular scalability, and durable construction, HICLOVER delivers advanced air filtration technology designed to meet the unique challenges of the Australian mining and resources sector.


Contact Information
Mobile (WhatsApp): +86-13813931455
Website: www.cloverfilter.com
Email: [email protected]


Mobile: +86-13813931455(WhatsApp)

Website: www.cloverfilter.com

Email:     [email protected] 

 

2025-09-02/17:33:13

HICLOVER Automatic Roll Air Filter for Australia’s Mining and Resource Facilities

HICLOVER Automatic Roll Air Filter for Australia’s Mining and Resource Facilities

Australia’s mining sector is one of the most advanced in the world, with operations covering iron ore, coal, gold, nickel, fertilizer, and energy production. The extreme dust loads and continuous air handling demands of these industries require specialized filtration systems. The HICLOVER Automatic Roll Air Filter is designed to meet these challenges by providing a robust, automated, and energy-efficient prefiltration solution for mining and bulk material handling environments.

Automatic Roll Air Filter for Conveyor Belt Transfer Stations Australia

Conveyor belt transfer stations are critical points in iron ore and coal logistics where significant dust emissions occur. Installing an automatic roll air filter for conveyor belt transfer stations in Australia ensures that coarse dust and fibers are captured before reaching sensitive ventilation or downstream filtration units. This technology prevents blockages in mine ventilation corridors, reduces wear on equipment, and improves the overall environmental performance of mining operations.

Self Advancing Filter Media System for Australian Underground Mines

In underground mining operations across Western Australia and Queensland, air quality management is essential for both safety and productivity. A self-advancing filter media system for Australian underground mines automatically rolls fresh filter material into place once differential pressure reaches a critical threshold. This ensures continuous ventilation without manual intervention, an important feature for remote or deep-level mines where maintenance access can be difficult. The PLC-controlled system and 0.1 kW three-phase gear motor guarantee reliable filter media replacement under high-dust conditions.

G3 Prefilter Roll for Australian Fertilizer and Resource Plants

Australia’s fertilizer and resource plants handle bulk chemicals and minerals such as phosphate, urea, and potash. Dust exposure in these facilities can compromise both worker health and product quality. The G3 prefilter roll for Australian fertilizer and resource plants provides coarse dust capture at HVAC intakes, reducing particulate load on downstream HEPA or fine filters. With its synthetic fiber media rated at G3 efficiency, the system is highly effective as a primary filtration layer in fertilizer production and mineral processing facilities.

Technical Highlights of HICLOVER Automatic Roll Air Filter

  • Air Volume Handling: Up to 26,000 m3/h, suitable for large industrial corridors.

  • Frame Materials: Powder-coated carbon steel, aluminum alloy, or stainless steel for corrosion resistance.

  • Smart Control: PLC automation with differential pressure sensors and remote alarm interfaces.

  • Filter Media: G3-grade synthetic fiber designed for coarse particle capture in mining and industrial applications.

  • Drive Motor: 100W three-phase gear motor ensures stable winding of filter rolls.

  • Modular Design: Units can be combined for large-scale ventilation systems.

Why HICLOVER in the Australian Market

  1. Harsh Condition Adaptability C Built to withstand dust-heavy operations in conveyor tunnels, fertilizer plants, and underground mines.

  2. Reduced Maintenance C Automated media advancement reduces manual filter replacement, critical for remote mining camps.

  3. Compliance Support C Helps meet Australian workplace air quality and environmental standards.

  4. Energy Efficiency C Prevents excess resistance in HVAC systems, lowering energy use.

  5. Industry Versatility C Applicable across mining, oil and gas, fertilizer, cement, and bulk handling facilities.

Conclusion

Australia’s mining and resource industries require filtration systems that are durable, intelligent, and efficient. The HICLOVER Automatic Roll Air Filter provides a tailored solution for conveyor transfer stations, underground mining corridors, and fertilizer plants, ensuring reliable dust control and continuous airflow. By integrating PLC control, modular design, and automated filter replacement, HICLOVER delivers unmatched performance for the Australian industrial landscape.


Contact Information
Mobile (WhatsApp): +86-13813931455
Website: www.cloverfilter.com
Email: [email protected]


Mobile: +86-13813931455(WhatsApp)

Website: www.cloverfilter.com

Email:     [email protected] 

 

2025-09-02/17:30:31

HICLOVER Automatic Roll Air Filter for Australia’s Mining and Energy Industries

HICLOVER Automatic Roll Air Filter for Australia’s Mining and Energy Industries

Australia is a global leader in mineral resources, with extensive reserves of nickel, lithium, iron ore, and oil & gas. From battery plants in Western Australia to iron ore conveyor tunnels in the Pilbara region, air quality management is critical for safe and efficient operations. The HICLOVER Automatic Roll Air Filter is engineered to meet these demands with advanced self-advancing prefilter technology, ensuring continuous airflow and effective dust control in some of the world’s harshest industrial environments.

Automatic Roll Air Filter for Australian Nickel and Lithium Battery Plants

The rapid expansion of nickel and lithium battery production in Australia has created a need for specialized air filtration systems. Facilities in Western Australia and Queensland handle high volumes of fine particulates during ore processing, smelting, and cathode material preparation.

The automatic roll air filter for Australian nickel and lithium battery plants integrates PLC-controlled filter media advancement. By continuously replacing saturated filter sections with fresh material, it provides stable prefiltration before HEPA or ULPA systems. This minimizes downtime and reduces contamination risks, supporting the stringent quality requirements of battery-grade materials.

High Airflow Roll Filter Unit for Australian Iron Ore Conveyor Tunnels

Australia’s iron ore industry, especially in the Pilbara, operates massive conveyor tunnels transporting thousands of tonnes of ore daily. These environments are subject to extreme dust concentrations, abrasive particles, and high-volume ventilation needs.

A high airflow roll filter unit for Australian iron ore conveyor tunnels ensures coarse dust capture at the intake stage. The G3-grade synthetic fiber media removes larger particles, protecting downstream equipment and reducing the frequency of secondary filter replacement. The modular design of HICLOVER roll filters allows multiple units to be combined, handling airflow capacities exceeding 25,000 m3/h.

Continuous Filter Roll System for Australian Oil and Gas Ventilation

In Australia’s oil and gas sector, ventilation corridors in offshore platforms, LNG plants, and refinery workshops require durable and automated filtration systems. A continuous filter roll system for Australian oil and gas ventilation ensures stable intake air quality for blowers, compressors, and HVAC units operating in corrosive marine and industrial conditions.

HICLOVER filters are constructed from powder-coated carbon steel, stainless steel, or aluminum alloy profiles, ensuring long-term resistance to harsh climates. The 0.1 kW three-phase gear motor drives a reliable winding mechanism, while differential pressure sensors trigger automatic filter replacement. This provides consistent airflow while reducing operational risks in remote oil and gas installations.

Technical Advantages of HICLOVER Automatic Roll Air Filter

  • Automatic Control: PLC-based system with manual override and differential pressure monitoring.

  • Filter Media: G3 synthetic fiber, ideal for coarse dust prefiltration.

  • Motor Drive: Low-power (100W) three-phase gear motor ensures stable winding.

  • Modular Assembly: Multiple units can be joined for higher air volumes.

  • Durability: Designed for dust-heavy mining environments, including iron ore, coal, and nickel processing plants.

  • Energy Savings: Automatic filter replacement prevents high resistance, reducing blower energy consumption.

Why HICLOVER for the Australian Market

  1. Adapted to Harsh Mining Conditions C Engineered for heavy dust loads and abrasive particles.

  2. Supports Compliance C Meets occupational air quality standards required by Australian regulations.

  3. Reduces Downtime C Automated filter media advancement minimizes manual replacement in remote mining camps.

  4. Flexible Applications C Suitable for nickel and lithium battery plants, iron ore conveyor tunnels, oil and gas facilities, and bulk handling terminals.

Conclusion

Australia’s mining and energy sectors demand filtration solutions that are robust, automated, and efficient. The HICLOVER Automatic Roll Air Filter provides a tailored solution for nickel and lithium processing plants, iron ore conveyor ventilation, and oil and gas facilities, ensuring safe, compliant, and energy-efficient operations across the country’s most critical industries.

For technical specifications and tailored solutions for Australian projects, contact HICLOVER today.


Contact Information
Mobile (WhatsApp): +86-13813931455
Website: www.cloverfilter.com
Email: [email protected]


Mobile: +86-13813931455(WhatsApp)

Website: www.cloverfilter.com

Email:     [email protected] 

 

2025-09-02/14:11:46

HICLOVER Automatic Roll Air Filter for Australian Mining Ventilation

HICLOVER Automatic Roll Air Filter for Australian Mining Ventilation

Australia is recognized globally as a leading exporter of minerals such as iron ore, coal, gold, nickel, and lithium. Mining operations across Western Australia, Queensland, and New South Wales require robust industrial ventilation systems to manage air quality in underground shafts, conveyor corridors, and bulk material handling facilities. In such demanding environments, the HICLOVER Automatic Roll Air Filter provides a proven and reliable solution for dust suppression and primary air filtration.

Automatic Roll Air Filter for Australian Mining Industry Ventilation

The automatic roll air filter for Australian mining industry ventilation is designed to handle high air volumes under low pressure conditions, making it ideal for mine intake corridors and ventilation ducts. By using G3 synthetic fiber filter media, the system captures coarse dust particles generated during drilling, blasting, crushing, and bulk handling. The automatic filter media advancement ensures that ventilation airflow remains stable, even in regions with high particulate concentrations typical of Australian mining environments.

Automatic Winding Air Filter System for Mine Ventilation Australia

HICLOVER’s automatic winding air filter system for mine ventilation in Australia integrates a PLC-controlled automatic and manual operating mode, allowing operators to adjust filter media replacement according to real-time differential pressure readings. When the filter resistance reaches the pre-set limit, the motor-driven winding mechanism automatically advances fresh filter material. This self-advancing prefilter technology reduces downtime and minimizes manual labor, a critical advantage for mines operating in remote locations across Australia’s outback.

Prefilter Roll System for Australian Bulk Material Handling Conveyors

Conveyor systems are the backbone of bulk material handling in iron ore and coal mines. Dust generated at transfer points and during loading creates operational risks for both machinery and personnel. A prefilter roll system for Australian bulk material handling conveyors helps stabilize airflow in ventilation corridors, capturing large particles before they reach downstream HEPA or secondary filtration units. This ensures the longevity of expensive filtration assets while supporting compliance with Australia’s strict occupational health and safety regulations.

Technical Advantages of HICLOVER Automatic Roll Air Filter

  • Frame Options: Cold rolled sheet with powder coating, aluminum alloy, or stainless steel for harsh environments.

  • Motor Drive: Three-phase integrated motor with low power consumption, engineered for continuous operation.

  • Filter Efficiency: G3-grade coarse filtration, suitable as a prefilter in multi-stage HVAC and mining ventilation systems.

  • Smart Control: PLC automation with differential pressure sensors, optional photoelectric detection, and remote alarm interfaces.

  • Modular Design: Multiple units can be assembled to match air volume requirements in mine corridors up to 26,000 m3/h or more.

Why Australian Mining Facilities Choose HICLOVER

  1. Adaptation to Harsh Environments: HICLOVER systems are engineered for dust-heavy conditions in open-pit and underground mines.

  2. Energy Efficiency: Automatic replacement of filter media reduces unnecessary pressure drops, improving blower efficiency and reducing energy costs.

  3. Compliance with Standards: Supports Australian environmental and workplace air quality regulations.

  4. Reduced Maintenance Costs: Automated winding systems reduce reliance on manual filter replacement, particularly valuable in remote mining camps.

  5. Versatility: Suitable for mining workshops, conveyor intake corridors, oil and gas facilities, desalination plants, and bulk terminals.

Conclusion

As Australia continues to expand its mining operations and strengthen its role as a global supplier of critical minerals, air quality and ventilation safety remain top priorities. The HICLOVER Automatic Roll Air Filter delivers intelligent, automated, and reliable filtration performance tailored to the unique challenges of the Australian mining and bulk material handling industries.

For operators seeking durable, PLC-controlled prefilter systems that reduce downtime, extend filter life, and comply with regulatory requirements, HICLOVER offers a solution built for the toughest conditions.


Contact Information
Mobile (WhatsApp): +86-13813931455
Website: www.cloverfilter.com
Email: [email protected]


Mobile: +86-13813931455(WhatsApp)

Website: www.cloverfilter.com

Email:     [email protected] 

 

2025-09-02/14:09:02

Pyrolytic Dual Chamber Incinerator Small Size : Burning Price : 30-45 kg/hr ; Optimum Load Capability : 400 kg

Items/Model

TS50( PLC)

Picture

Principle

Strong Waste Incineration

Burn Price

30-45 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

560L

Inner Measurements

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

220V

Oil Intake (kg/hour)

Typical 13.3

Gas Consumption (m3/hour)

***

Temperature Display

Digital Show

Temperature Level Defense

Yes

Oil Storage Tank

800L

Feed Door

70x55cm

Chimney

5Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature Level

800 ℃– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

Exterior Measurements

230x130x155cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Tool Dimension : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Incinerator

Items/Model

TS100( PLC)

Photo

Concept

Waste Incineration Treatment

Burn Price

60-80 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Combustion Chamber

1200L

Interior Measurements

120x100x100cm

Second Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Setting

Manual

Voltage

220V

Oil Consumption (kg/hour)

Typical 20.4

Gas Intake (m3/hour)

***

Temperature Monitor

Digital Present

Temperature Level Defense

Yes

Oil Container

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Plus Size Burning Price : 150-200 kg/hr Solid Waste Devices Primary and Second Combustion Chamber Burner

Items/Model

TS500( PLC)

Picture

Concept

Waste Incineration Treatment

Burn Price

150-200 kg/hour

Control Setting

PLC( Programmable Logic Controller Burner)

Combustion Chamber

2700L

Interior Dimensions

190x120x120cm

Second Chamber

1300L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Oil Intake (kg/hour)

Ordinary 28

Gas Usage (m3/hour)

***

Temperature Display

Digital Display

Temperature Security

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

15000kg

Outside Measurements

400x210x300cm( without chimney)

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21