Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day).
Items/Model
TS50(PLC)
Picture
![]()
Principle
Waste Incineration Treatment
Burn Rate
Average 50-100 kg/hour
Feed Capacity
Average 200-300 kg/feeding
Control Mode
PLC(Programmable Logic Controller Incinerator)
Optional Upgrade Containerized Mobile Type Incinerator
ISO 20′ Full Container
Combustion Chamber
560L
Internal Dimensions
1000x800x700mm
Secondary Chamber
280L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
210/240V 50Hz 1P
Power
1.3Kw
Oil Consumption (kg/hour)
Average 20.4(D.O)
Thermal capacity(kw/hour)
166-332
Gas Consumption (m3/hour)
***
Temperature Monitor
Digital Display
Oil Tank
1000L
Feed Door
60x50cm
Chimney
10Meter
Chimney Type
Stainless Steel
1st. Chamber Temperature
800℃–-1000℃
2nd. Chamber Temperature
1000℃-1200℃
Residency Time
2.0 Sec.
Gross Weight
7500kg
External Dimensions
260x160x250cm(without chimney)
Feb, 2026
Double Chamber Incinerator on sale 50-200kgs per hour(in stock)

|
Main Product List per 01 set |
Primary Combustion Chamber |
|
Secondary Combustion Chamber |
|
|
Smoke Filter Chamber |
|
|
Incinerator PLC Control Case |
|
|
Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) |
|
|
Italy oil/gas burner: 02 units |
|
|
Oil Tank (if oil fuel): 300Liters |

Items/Model
TS150(PLC)
Principle
Waste Incineration Treatment
Burn Rate
Average 50/100/150/200 kg/hour
Feed Capacity
Average 750kg/feeding
Control Mode
PLC(Programmable Logic Controller Incinerator)
Combustion Chamber
1570L
Internal Dimensions
150x100x105cm
Secondary Chamber
750L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
210/230V 50/60Hz
Power
0.9Kw
Oil Consumption (kg/hour)
Average 20.4(D.O)
Thermal capacity(kw/hour)
166-332
Gas Consumption (m3/hour)
***
Temperature Monitor
Digital Display
Temperature Protection
Yes
Oil Tank
300L
Feed Door
80x60cm
Chimney
10Meter
Chimney Type
Stainless Steel
1st. Chamber Temperature
800℃–-1000℃
2nd. Chamber Temperature
1000℃-1200℃
Residency Time
2.0 Sec.
Gross Weight
8500kg
External Dimensions
300x160x280cm(without chimney)
Feb, 2026
BIOHAZARD DISPOSAL INCINERATOR CONTAINERISED IN A 20 FT CONTAINER
BIOHAZARD DISPOSAL: CONTAINER
GENERAL INCINERATOR, IDEAL FOR INCINERATION OF VARIOUS TYPES OF WASTE, FULLY CONTAINERISED IN A 20 FT CONTAINER, TO INCLUDE BUILT-IN FUEL TANK AND GENERATOR.
TECHNICAL SPECIFICATIONS: COMBUSTION CHAMBER VOLUME (M3); 0.54 m3. SUGGESTED BATCH SIZE: 60 KG, BURN RATE: 69 KG PER HOUR, AVERAGE FUEL CONSUMPTION 13 KG PER HOUR, OPERATIONAL TEMPERATURE: 950-1320 CELSIUS, GAS RETENTION IN SECONDARY CHAMBER 0.5 SECS, WITH TEMP. MONITORING , AVERAGE ASH RESIDUE: 3%, THERMOSTATIC DEVICE: YES,
DIMENSIONS: EXTERNAL LENGTH (mm): 1520MM, EXTERNAL WIDTH (mm): 920MM, EXTERNAL HEIGHT (mm): 4020 MM
1. Incinerator for Bio-Medical Waste incineration needed
2. 50 kg/hr
3. 2 chambers must be there
4. temperature of primary chamber should be 850 degrees Celsius
temperature of secondary chamber should be 1200 degrees Celsius
Feb, 2026
How you can find reasonable incinerators for your local site?
Hiclover supply medical waste incinerators with capacity 10kgs per hour to 500kgs per hour.
The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from
Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour
and 50kgs per hour.
We are famous small scale incinerator manufacturer and brand, dispatch incinerator productsand best services with lower price for customer all around the world.How you can find reasonable incinerator for your local site?
Incinerator is not a cheap equipment, generally the small scale model’s price around $5,000usd per unit
and large scale model’s price more than $50,000usd per unit. So, before purchase one unit incinerator,
you have to make clear following items:
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of
waste you want to treatment?
B, small or large? This according to the waste output every day or the waste volume per
feed time, like animal size.
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke
cleaner than oil fuel model. But some local site don’t have gas supply system.
And other technology items, like power(220v, 380v), waste feed door type, incinerator structure, etc.
Nanjing Clover Medical Technology Co.,Ltd.Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm Chimney 3Meter 3Meter 5Meter 5Meter 10Meter Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
Feb, 2026
an animal cremator
an animal cremator for our business in malaysia.currently we are doing individual private cremation and mass cremation for pets as well as medical waste.an incinerator which is capable of burning between 3 to 5 tonnes per day of mixed waste products, plastics, rubber, flammable putrescible waste, medical waste, rubber tyres, paper and cardboard, textiles, green timber waste etc. As some of the waste products will contain non-flammable solids, the incinerator should be capable of extracting those materials probably via a rotary kiln process.
It is not intended to use any fuel, such as oil or diesel, to promote the burning of the waste, as the waste products are required to be incinerated using a free burning process. Hot air however from a downstream process will be available to increase the incinerator temperature and burning rate as required. Very high temperatures in the incinerator are not necessary and are not required.
The burning of the waste products is expected to produce toxic emissions which will be cleaned via other existing downstream processes and a Post Combustion process in the incinerator is therefore not required.
The incinerator should be capable of accommodating an automatic waste feed process.Incinerator Specification
S. No.
Description
1
Feeding Capacity
100 Kg.
2
Burning Capacity
50 Kg. / Hour
3
Feed Mode
Manual
4
Fuel
Diesel Oil
5
Incinerator Type
Dual Combustion Chamber with Built in Smoke Filter ( Dry Scrubber )
6
Chimney Material
Non Corrosive / Corrosion Resistant Preferably Stainless for longer Life (Height 5-7 Meter)
7
Burners
High Quality European CE Certified Oil Burner
8
Control Panel
Standard PLC Control Panel
9
Power Supply
220/380 Volt Ac 50 Hz.
10
Oil Tank Capacity
200~~ 300 Litre
11
Burning Chamber
Fire Brick, Refractoy Brick, Concrete
Feb, 2026
Waste incinerators spare parts
HICLOVER now offers spare parts including:
— Burners (diesel oil, LPG or natural gas)
— Element for burners
— Fire ropes
— Incinerator chamber maintenance materials
— Air Fan
Feb, 2026
incinerate biohazard waste
an incinerator which is capable of burning between 3 to 5 tonnes per day of mixed waste products, plastics, rubber, flammable putrescible waste, medical waste, rubber tyres, paper and cardboard, textiles, green timber waste etc. As some of the waste products will contain non-flammable solids, the incinerator should be capable of extracting those materials probably via a rotary kiln process. We are however open to suggestions on the issue of the rotary kiln solution as you may have other solutions available.
It is not intended to use any fuel, such as oil or diesel, to promote the burning of the waste, as the waste products are required to be incinerated using a free burning process. Hot air however from a downstream process will be available to increase the incinerator temperature and burning rate as required. Very high temperatures in the incinerator are not necessary and are not required.
The burning of the waste products is expected to produce toxic emissions which will be cleaned via other existing downstream processes and a Post Combustion process in the incinerator is therefore not required.
The incinerator should be capable of accommodating an automatic waste feed process.We are looking for incinerator to incinerate biohazard waste of our microbiology lab. Our daily waste production is upto 20 Kg maximum and incinerator will be required on weekly basis that is 1 or 2 times a week so you are therefore requested to kindly suggest the appropriate incinerator for our lab which shall be cost effective for us regarding purchasing and maintenance cost.
Jan, 2026
Hiclover bio waste incineration
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce.※Main Feature:
— Double Combustion Chamber
— Double Italy Burner
–Burning Rate: 10-100kgs per hour
–Combustion Chamber: 0.1M3-1.2M3
— Mobile Incinerator, Standard shipping containers, Easy to move/transport system
— Free Installation, Pre-installed incinerator, Ideal for camps
— Ultraviolet lamp sterilization inside
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm Chimney 3Meter 3Meter 5Meter 5Meter 10Meter Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm Equipment Double chamber medical infectious waste incinerator Capacity 10-30 kg per hour Characteristics of waste
Mainly syringes and needles from immunization routine and campaign activities. However, the following average characteristics are considered*:
heating value above 2000 kcal/kg (8370 kJ/kg); content of combustible matter above 60%; content of non combustible solids below 5%; content of
non-combustible fines below 20%; moisture content below 30% by weight
Combustion performance: The medica waste incinerator shall be capable of reducing waste to ash not exceeding 10% of the total combustible
charges.
Outdoor installation. The medical waste incinerator will be installed outdoors. All incinerator components shall be suitable for but not
limited to outdoor shaded installation, including electric motors, be resistent to corrosion, moisture and related weather elements.Materials of construction: The incinerator shall not have any asbestos, asbestos-containing substances, mercury thermometers, and mercury
switches. Refractory materials shall be able to meet relevant standards under ISO TC33 and CEN/TC 187.Types of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air FiltersNanjing Clover Medical Technology Co.,Ltd.
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Jan, 2026
an industrial sized incinerator for tobacco and tobacco waste
inciner8ter model TS50 OR TS100 With delevery in Europe stare Croatia.Please can you send me the offer for pet crematory equipment.details of Chemical waste incinerator.
For animals to 90 kg. cremation equipment for pets ( Max. Size dogs till 80 kg )1. technical specification is for burner only
2what is the capacity of burner in one hour?
3. 35 for burners, 8 for control case, 1 for HD is that the weight of each item?
4. are these already configured so that the assembling becomes easy between control case and burners with HD?oil burner, 2sets (bigger capacity)
Temperature Thermocouple, 2 sets
Oil Tank 100Liters, 1 set
Thermal Gasket, 10 Meters
Incinerator control Case, 1 set
Blower, 1 set.an industrial sized incinerator for tobacco and tobacco waste. Details
Brand = Any
Model = Any
400v/50hz
· Types of waste – woods, tree branches, tree leaves, wood powder and card boards
· Daily Hours of operation = 7 hours
· Per day produce waste capacity = 10000kg
THEE SETS OF CATALOGUE ORIGINAL SHOULD BE RECIVED BY DHL + CD VEDIO
THREE YEARS GUARANTEE FREE FREOM DELIVARY DATE AND FREE SPAR PART ALSO, GARANTEE LATTER SPAR PART SHOULD BE VALID FOR 10 YEARS FROM THE DATE OF DELIVEARY .
ELECTRIC UNIT SHOULD BE DELIVERD WITH SERVIC MANUAL IN ENGLISH FOR EACH ONE
ELECTRIC SHOULD BE 380-220 V HZ 60 FOR ALL EQUIPMENTS
DELIVER TIME ASB
OFFER VALIDITY SHOULD BE 6 MONTHS
IN CASE OF ORDER I NEED
TWO SETS OF CERTIFICATE OF ORGINE SHOULD BE STAMPED IT FROM SAUDIA EMBASSY IN YOUR COUNTRY
COMMERCAL INVOICE( LEGALIZED FRO CHAMPER OF COMMERCE)
TWO ORGINAL BILL OF LADIN
should BE SEND SOME ONE FOR FIXE AND TRANING FOR 5 PERSON IN EACH LOCATION
SHOULD BE SEND YOUR DIZIN FOR INSTALATION UNITS
AWITING YOUR GOOD REPLY
Jan, 2026
A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE
SPECIFICATIONS OF A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE
1. Capacity of destruction in weight: 500 kg/h.
2. It should be able to operate not less than 8 hours/day
3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
4. Design Specification : Types A, B, C, D, and E of medical waste
5. “PYROLYTIC” combustion, by controlling the gasification of waste.
6. The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.
7. It should be able to reduce the volume of wastes by 98%.
8. It should be able to hold emission in the second burn with gas residence of not less than 2
seconds.
9. The incineration should be completely free from visible smoke as well as offensive odours.
10. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
• The Temperatures of combustion: Minimum will be 850oC and max 1400oC
• Post combustion: >1100oC.
11. The Internal diameter of the Chimney: Ø 400 and its height: 8 m
12. The Volume of the combustion chamber: 1.200 L
13. The Dimension of the door for loading in cm: 120×120.
14. Burner operation should be Automatic On/Off
15. Fuel : diesel/Gas
16. The supplier must provide necessary information for the best of the installation This incinerator with “PYROLYTIC” combustion must have:
17. A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch
Load
* A burner of lighting which the use is limited to the ignition of waste.
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on
the outside sheet metal.
* Composition of the refractory;
• Refractory concrete :
▪ . Thickness : ≥100 mm
▪ . Nature: 42% of Al203
• Insulate in fibrous panels :
▪ . Thickness: ≥75 mm
• Nature: Calcium silicate.
* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.
18. A chamber of post combustion of gases
* A burner of combustion of gases,
* A device of injection of air allowing a total recombustion of gases,
* A device of air inlet of cooling of waste gases,
* A sheath of evacuation of the gases burnt.
* Carcass in strong sheet steel with support of connection.
* Composition of the refractory;
• Refractory concrete :
▪ Thickness : ≥150 mm
▪ Nature: 65% of Al203
• Insulate in fibrous panel :
▪ Thickness: ≥85 mm
▪ Nature: Calcium
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* A secondary injection of air to ensure perfect oxygen content.
19. A control box ensuring the complete cycle of combustion.
20. A Pollution control device connected to the flue chimney must be connected to prevent
unnecessary escape of pollutants
21. Fan:
* Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
22. Controls and regulations:
Control box watertight to dust, including:
* A switch circuit breaker for each engine (ventilators and burners).
* A timer with adjustable temporization for the regulation of each burner.
* A regulator with digital watching for the temperature of combustion.
* A regulator with digital watching for the temperature of post combustion.
* Electric box.
21. The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing.
22. Process Filtering system : Scruber to be mentionned as optional
23. Emission Standards Compliance: BS 3316 or équivalent standard
23. Capacity to treat Plastic: Not less than 40% by weight
24. CE Manufacturing Compliance: BS EN 746-2-1997
23. The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
24. The installed incinerator must bear a one year guarantee.
25. The supplier shall perform an onsite installation of the incinerator.
25. The technical training of operators will have to be provided and given by a technician from the factory; it will consist of curative and preventive maintenance, and the use of machine, etc
NB.: Civil works and any other related services for the installation and training of operators must be included in the incinerator’s price.