Liquid tank high efficiency filter

May 13, 2019 air filter 356 views


Ecol ead liquid tank high efficiency filter

Product Features:

l    Frame: Anodized aluminum extrusion profile

l    Frame thickness: 70, 90MM, etc.

l    Filter material: ultra-fine glass fiber filter paper

l    Maximum temperature: 70℃

l    Maximum humidity: 99%

l    Efficiency: 99.99%@0.3um (H13) 99.999%@0.3um (H14)

Applications:

l    It is widely used in the terminal filtration of clean workshop with vertical air supply.

Common specifications and performance parameters

Dimensions ( WxHxDmm )

Rated air volume ( m3/h )

Initial resistance ( ≤Pa )

Final resistance ( Pa )

Filter area (㎡)

Dust holding capacity ( g )

Filtration efficiency

346x346x90

400

200

400-600

4.20

250

H13-H14

510x510x90

900

200

400-600

9.42

565

H13-H14

636x636x90

1500

200

400-600

14.90

900

H13-H14

636x941x90

2000

200

400-600

22.30

1200

H13-H14

626x1226x90

2800

200

400-600

29.80

1800

H13-H14

510x510x69

700

200

400-600

6.60

400

H13-H14

636x636x69

1000

200

400-600

10.70

650

H13-H14

596x1196x69

1800

200

400-600

18.30

1100

H13-H14

636x1236x69

2100

200

400-600

21.30

1000

H13-H14

621x621x90

1380

200

400-600

14.19

851

H13-H14

636x1246x90

2800

200

400-600

29.80

1800

H13-H14

569x1196x90

2550

200

400-600

26.28

1577

H13-H14

656x994x90

2350

200

400-600

24.15

1449

H13-H14

1. In case of specification and structure changes, the latest data provided by our company shall prevail

2. The company accepts orders for filters that are not specified in the table

More content URL: www.ecolead.cn Tel: 025-57138032

What are the maintenance points of the Nanjing single double air shower room

May 22, 2019 Industry News 210 views

As we all know, the maintenance of the environment is an indispensable part in the process of using the entire Nanjing single and double air shower room. If it is not well maintained, no matter how good the product is, no matter how expensive it is, it will be useless and will shorten the service life of the equipment. I believe that no matter which user it is, he does not want the air shower room he uses to have a short service life. Therefore, mastering the main points of maintenance and prolonging the service life is easy.

1. According to the actual usage and the cleanliness of the dust-free workshop, remove the primary filter regularly, clean it or install it directly with a new filter. In daily operation and use, once you find that the wind speed is slowly decreasing, you need to take out the primary filter to see if its appearance has darkened to increase the resistance. If there is too much dust filtered and the filter screen has been blocked, it means that there is more dust in the filter and there is a great resistance. The non-woven fabric in the filter needs to be removed for cleaning or replacement.

2. After replacing or cleaning the non-woven fabric, the wind speed cannot be restored to the original level, which means that the high efficiency filter has also been blocked, so that such a large resistance will be generated, and the high efficiency filter needs to be replaced.

3. When replacing, remove the whole plate with the spray ball in the middle to take out the high efficiency filter. According to the original filter specification and model, contact the manufacturer to order the same type of high efficiency filter for replacement.

4. During the installation process, pay attention to the airflow direction indicated by the arrow on the filter to determine the air inlet and outlet surfaces. Tighten the filter locking mechanism to ensure a good seal and prevent leakage.

5. After the high-efficiency filter is replaced, it is necessary to check whether there is any leakage in the frame, and use a dust particle counter to conduct a leakage test. After reaching the technical indicators, normal use can be resumed.

6. If the electrical circuit needs to be overhauled on a regular basis, once there is a fault, it will be repaired according to the electrical schematic diagram. Maintain the door so that the electronic lock is aligned with the key hole to avoid the lock pin from getting stuck.

7. The temperature used in this single-person double-air shower room cannot be above 50°C. Pay attention to the daily fire-proof and temperature-resistant work.

When using a single double blower shower room , you need to master the above maintenance points. When the filter needs to be replaced, replace the high-efficiency or primary-efficiency filter with a new one in time to reduce resistance, reduce damage to the air shower, and maximize the wind speed of the spray ball. In order to avoid any impact on the use of the air shower, it will become even worse.

More content URL: www.ecolead.cn Tel: 025-57138032

High temperature resistant high efficiency filter

May 13, 2019 air filter 297 views


Ecolea d high temperature resistant high efficiency filter

Product Features:

l    Outer frame: stainless steel frame

l    Filter material: ultra-fine glass fiber filter paper

l    Maximum temperature: 250℃ 320℃

l    Maximum humidity: 99%

l    Efficiency: 99.99%@0.3um (H13) 99.999%@0.3um (H14)

Applications:

l    Hot air filtration in high-temperature environments, aseptic systems and ovens and other high-temperature places to filter fine particles

Initial resistance-air volume relationship curve

Common specifications and performance parameters

type    number

Dimensions

Filter area (m 2 )

Rated air volume (m 3 /h)

Initial pressure drop (Pa)

Width × height × depth (mm)

Mark    quasi-

High air volume

Mark    quasi-

High air volume

H10

H12

H13

H14

TR320

320×320×220

4.1

6.1

350

525

≤160

≤200

≤235

≤255

TR484/10

484×484×220

9.6

14.4

1000

1500

TR484/15

726×484×220

14.6

21.9

1500

2250

TR484/20

968×484×220

19.5

29.2

2000

3000

TR630/05

315×630×220

8.1

12.1

750

1200

TR630/10

630×630×220

16.5

24.7

1500

2250

TR630/15

945×630×220

24.9

37.3

2200

3300

TR630/20

1260×630×220

33.4

50.1

3000

4500

TR610/03

305×305×150

2.4

3.6

250

375

TR610/05

305×610×150

5.0

7.5

500

750

TR610/10

610×610×150

10.2

15.3

1000

1500

TR610/15

915×610×150

15.4

23.1

1500

2250

TR610/20

1220×610×150

20.6

30.9

2000

3000

TR610/05X

305×610×292

10.1

15.1

1000

1500

TR610/10X

610×610×292

20.9

31.3

2000

3000

1. In case of specification and structure changes, the latest data provided by our company shall prevail

2. The company accepts orders for non-listed filter products

More content URL: www.ecolead.cn Tel: 025-57138032

High-efficiency separator filter

May 13, 2019 air filter 330 views


Product Features:

l    Outer frame: wooden frame, galvanized frame, aluminum alloy frame or stainless steel frame

l    Frame thickness: 150, 220, 290MM, etc.

l    Filter material: ultra-fine glass fiber

l    Maximum temperature: 80℃

l    Maximum humidity: 99%

l    Efficiency: 99.99%@0.3um (H13) 99.999%@0.3um (H14)

Applications:

l    Mainly used in the electronics, biopharmaceutical industry and hospitals where high cleanliness is required  

Initial resistance-air volume relationship curve

Common specifications and performance parameters

type    number

Dimensions

Filter area

(m 2 )

Rated air volume

(m 3 /h)

Initial pressure drop

(Pa)

Width × height × depth (mm)

Mark    quasi-

High air volume

Mark    quasi-

High air volume

F8

H10

H13

TH230

230×230×110

0.8

1.4

110

180

≤85

≤175

≤235

TH320

320×320×220

4.1

6.1

350

525

TH484/10

484×484×220

9.6

14.4

1000

1500

TH484/15

726×484×220

14.6

21.9

1500

2250

TH484/20

968×484×220

19.5

29.2

2000

3000

TH630/05

315×630×220

8.1

12.1

750

1200

TH630/10

630×630×220

16.5

24.7

1500

2250

TH630/15

945×630×220

24.9

37.3

2200

3300

TH630/20

1260×630×220

33.4

50.1

3000

4500

TH610/03

305×305×150

2.4

3.6

250

375

TH610/05

305×610×150

5.0

7.5

500

750

TH610/10

610×610×150

10.2

15.3

1000

1500

TH610/15

915×610×150

15.4

23.1

1500

2250

TH610/20

1220×610×150

20.6

30.9

2000

3000

TH610/05X

305×610×292

10.1

15.1

1000

1500

TH610/10X

610×610×292

20.9

31.3

2000

3000

1. In case of specification and structure changes, the latest data provided by our company shall prevail

2. The company accepts orders for non-listed filter products

More content URL: www.ecolead.cn Tel: 025-57138032

The purpose and characteristics of the hundred-class clean shed

May 22, 2019 Industry News 236 views

Class 100 clean shed is a simple clean room that is simple, quick and easy to build, with low investment cost, and the construction effect is no different from that of a clean room. It also has a variety of cleanliness grades to choose from, and can be designed and manufactured according to customer needs. So what are the uses and characteristics of the clean shed? Look at the following analysis:
Class 100 clean shed is a kind of flexible, easy to install, short construction period and convenient to move. Partial additions can also be made according to the working environment required by a general-grade clean room to reduce costs, so as to achieve the cleanliness required for work, and is beautiful and overall. Generally, stainless steel, sprayed plastic, and industrial materials can be used as the overall frame. The top is used for unit air supply, and the surrounding is surrounded by anti-static curtains or glass partitions. It is a clean equipment with strict environmental requirements for modern technology. It is also used in pharmaceutical factories, hospitals, food processing, liquid crystals and other places where local purification is required.
Features of the 100-class clean shed:
1. The frame structure design is convenient for installation, can be used for secondary use, and meets the requirements of environmental protection.
2. The top module structure uses high-efficiency filters to improve cleanliness, with strong scalability and high value for repeated use.
3. Adopt low-noise fan system with long service life and stable performance.
4. Sectional speed regulation of the governor can ensure the desired ideal state.
5. The bottom is equipped with universal wheels, which is convenient for positioning, flexible movement and convenient operation.
6. It has a good effect on improving the efficacy of the product. Thereby improving the production quality of products.
7. Compared with the clean workbench, the 100-class clean shed has a larger internal available space, but compared to the clean room, the cost is lower and it is convenient for combined installation.
8. In the selection of the hundred-level clean shed, a pressure difference meter can be installed to understand the pressure difference between the inlet and outlet surfaces of the filter, and to know the replacement time of the filter in time.
In short, the Class 100 clean shed is a kind of clean equipment that can provide clean ambient air locally. It is mainly composed of fans, air filters, lamps, etc. The shell is made of plastic spraying. The one-hundred-level clean shed can be hung and supported on the ground, which is more convenient to use. It can be used not only individually but also in multiple assemblies.

More content URL: www.ecolead.cn Tel: 025-57138032

High efficiency/super high efficiency no partition filter

May 13, 2019 air filter 345 views


Ecolea d high-efficiency/super high-efficiency non-partition filter

Product Features:

l    Frame: Anodized aluminum extrusion profile

l    Frame thickness: 70, 90MM

l Filter material: ultra-fine glass fiber filter paper

l    Separation line: hot melt adhesive

l    Maximum temperature: 80℃

l    Maximum humidity: 99%

l    Efficiency: 99.99%@0.3um (H13) 99.999%@0.3um (H14)

99.9995%@0.3um (U15) 99.99995%@0.3um (U16)

Applications:

l    Mainly used in the electronics, biopharmaceutical industry and hospitals where high cleanliness is required

Initial resistance-air volume relationship curve

Common specifications and performance parameters

type    number

Dimensions

Filter area

(m 2 )

Rated air volume

(m 3 /h)

Rated wind speed

(m/s)

Initial pressure drop

(Pa)

Width × height × depth (mm)

MH610/03-50

305×305×50

1.6

150

0.5

≤190

MH610/05-50

305×610×50

3.3

300

MH610/10-50

610×610×50

6.7

600

MH610/15-50

915×610×50

10.1

900

MH610/20-50

1220×610×50

13.5

1200

MH610/03-70

305×305×70

2.7

250

0.75

MH610/05-70

305×610×70

5.5

500

MH610/10-70

610×610×70

11.3

1000

MH610/15-70

915×610×70

17.0

1500

MH610/20-70

1220×610×70

22.7

2000

MH610/03-90

305×305×90

3.7

320

1.0

MH610/05-90

305×610×90

7.5

650

MH610/10-90

610×610×90

15.4

1300

MH610/15-90

915×610×90

23.2

2000

MH610/20-90

1220×610×90

31.1

2600

1. In case of specification and structure changes, the latest data provided by our company shall prevail

2. The company accepts orders for non-listed filter products

More content URL: www.ecolead.cn Tel: 025-57138032

Filtration principle and installation requirements of thousand-grade clean shed

May 22, 2019 Industry News 212 views

A thousand-grade clean shed refers to the removal of harmful gases, bacteria and other pollutants in the air in a fixed space, and the indoor temperature, cleanliness, indoor pressure, airflow distribution, and static electricity are controlled within a certain specified range. Special design is given A simple isolation and purification system that meets the expected demand.

       The filtering principle of the thousand-grade clean shed filter:

After the small particles of dust in the thousand-level clean shed are diffused significantly, the wind speed is significantly reduced, the airflow residence time is longer, and the dust hits the obstacle, so the filtration efficiency is higher. For high-efficiency filters, when the wind speed is reduced by half, the dust passing rate will be reduced by one level, and when the wind speed is doubled, the dust passing rate will double.

       In a situation similar to the diffusion effect of a thousand-grade clean shed, when the filter material is charged with static electricity, the longer the dust filtering time, the higher the possibility of being adsorbed. Changing the wind speed will change the efficiency of the electrostatic filter. When removing static electricity on the material, design the air conditioner to reduce the air volume of each filter as much as possible. The higher the wind speed, the greater the resistance, if the service life of the filter will be based on the resistance. The higher the wind speed, the shorter the service life of the filter. According to the traditional theory, after the wind speed is reduced, the collision probability between the fiber and the dust will be reduced, and the filtering efficiency will be reduced. This phenomenon is not obvious, because the wind speed is small, the rebound force of the fiber is also small, and the dust is more likely to be stuck.

      Installation requirements for thousand-grade clean shed:

1. All the clean sheds in the maintenance factories of the prefabricated dust-free workshops are processed in accordance with the uniformly specified parameters, which is suitable for mass production of products, stability of quality, and speed of supply.

2. The production workshop is more flexible, which is not only suitable for installation in newly-built workshops, but also suitable for the purification and transformation technology of the workshop. It can also be combined freely according to the needs of the process during maintenance, which is convenient for disassembly.

3. The area required for a thousand-level clean shed is small, and the requirements for building decoration are low. As long as the FFU is arranged according to the cleanliness level, the expected purification effect can be achieved.

4. The airflow organization in the workshop is reasonable, which can meet all kinds of work requirements and any working environment. It also meets the requirements of different cleanliness levels. It is a flexible and simple dust-free workshop.

More content URL: www.ecolead.cn Tel: 025-57138032

High efficiency V-type filter

May 13, 2019 air filter 318 views


Ecolea d high efficiency V-type filter

Product Features:

l    Outer frame: plastic frame, galvanized frame, aluminum alloy frame or stainless steel frame

l    Filter material: ultra-fine glass fiber or polypropylene

l    Separator: hot melt adhesive

l    Maximum temperature: 80℃

l    Maximum humidity: 99%

l    Efficiency: 99.99%@0.3um (H13) 99.999%@0.3um (H14)

Applications:

l    Widely used in air-conditioning purification equipment with large air volume

l    Fields that have strict requirements on air cleanliness, such as terminal filtration of air-conditioning box systems

Initial resistance-air volume relationship curve

Common specifications and performance parameters

type    number

Dimensions

Knot    Structure

frame    body

Filter area

(m 2 )

Rated air volume

(m 3 /h)

Initial pressure drop

(Pa)

W×H×D (mm)

F8

H10

H13

MV1212-2VF25

287×287×292

287

Single convex

25mm

2V

Plastic frame / metal frame

4.2

800

110

180

260

MV1220-2VF25

287×490×292

7.7

1200

MV1224-2VF25

287×592×292

9.4

1600

MV2012-3VF25

490×287×292

490

Single convex

25mm

3V

Plastic frame / metal frame

6.4

1100

MV2020-3VF25

490×490×292

11.6

1900

MV2024-3VF25

490×592×292

14.4

2400

MV2412-3VF20/25

592×287×292

592

Single convex

20/25mm

3V

Plastic frame / metal frame

6.4

1100

MV2420-3VF20/25

592×490×292

11.6

1900

MV2424-3VF20/25

592×592×292

14.4

2400

MV2412-4VF20/25

592×287×292

4V

Plastic frame / metal frame

8.4

1600

MV2420-4VF20/25

592×490×292

15.4

2500

MV2424-4VF20/25

592×592×292

18.8

3200

MV2412-5VF25

592×287×292

592

Single convex

25mm

5V

Plastic frame / metal frame

10.5

1800

MV2420-5VF25

592×490×292

19.0

3200

MV2424-5VF25

592×592×292

23.5

3900

MV1212-2V

305×305×292

610

Box

2V

Plastic frame / metal frame

5.4

850

MV1224-2V

305×610×292

10.8

1700

MV2412-4V

610×305×292

4V

Metal frame

11

1700

MV2424-4V

610×610×292

twenty two

3400

MV2412-5V

610×305×292

5V

Plastic frame / metal frame

13.5

2100

MV2424-5V

610×610×292

27

4200

MV2412-6V

610×305×292

6V

Metal frame

16

2500

MV2424-6V

610×610×292

32

5000

1. In case of specification and structure changes, the latest data provided by our company shall prevail

2. The company accepts orders for filters that are not specified in the table

More content URL: www.ecolead.cn Tel: 025-57138032

Talking about the transportation and packaging of the coiled air filter

May 22, 2019 Industry News 174 views

Coiled air filters are widely used in sewage treatment plants, chemical plants, waste gas treatment plants and other major factories, involving a wide range of industries, so the scope of use is also very broad, so its transportation and packaging costs are also very high Therefore, for many companies, how to save transportation and packaging costs has become a very difficult problem for companies. The following editor will give you some suggestions on transportation and packaging for your reference.

The volume of the coiled air filter is a large-scale equipment. Its volume ranges from 1 cubic meter to less than 10 cubic meters. In view of the geographical differences between the production enterprises and the demanding enterprises, the cost of shipping, transportation and packaging has become a problem for both parties. In fact, for the transportation of large items, it is all carried out by freight, but the freight process is unavoidable. Therefore, the packaging problem needs to be solved urgently.

We suggest that all coiled air filters should be packaged in wooden boxes, because wooden box packaging is more practical, and it is especially suitable for items that are afraid of collisions, and wooden packaging will improve the humidity of the air to a certain extent. Because the equipment encounters rain and atmosphere during transportation, the water ingress and humidity increase affect the performance of the equipment, and some serious ones can also cause the equipment to rust and damage the parts. Therefore, it is recommended to use wooden box packaging to achieve two goals. For transportation, automobile transportation is more adopted. Firstly, the delivery cycle is short, and secondly, the short cycle will cause less environmental impact on the equipment on the road, so the damage to the equipment will be less.

The transportation and packaging of the coiled air filter can not be ignored. The quality of the packaging directly affects the performance of the equipment. If the air filter is damaged, the air filtration will be incomplete, so sewage treatment and waste gas treatment will not be achieved. The required standards are not beneficial to the enterprise and the overall social environment. Therefore, both transportation agencies and consignment companies must pay attention to transportation and packaging. Ensure that the life and interests of enterprises and the general public are not harmed.

 

More content URL: www.ecolead.cn Tel: 025-57138032

Medium efficiency/sub-high efficiency box filter

May 13, 2019 air filter 318 views

Ecolead medium efficiency/sub-high efficiency box filter

Product Features:

l    Outer frame: plastic frame, galvanized frame, aluminum alloy frame or stainless steel frame

l    Frame thickness: 70, 90, 150, 220MM, etc.

l    Filter material: chemical fiber non-woven fabric

l    Maximum temperature: 93°C

l    Maximum humidity: 99%

l    Efficiency: F5, F6, F7, F8, F9 (EN779)

Applications:

l    Pre-filtration of air-conditioning and ventilation systems to avoid dust pollution inside the system

l    Large-scale air compressor pre-filtration, return air filtration of centralized ventilation and air-conditioning systems in clean rooms, extending high-efficiency life

l    The ventilation and filtration of ordinary industrial plants meet the general clean air requirements

Common specifications and performance parameters

Specification and size ( WxHxDmm ) Rated air volume ( m3/h ) Initial resistance ( ≤Pa ) Final resistance ( Pa ) Filter area ( m2 ) Dust holding capacity ( g ) Filtration efficiency
592x592x292 2890 50 250-300 4.46 803 F5
592x592x292 2890 65 250-300 4.46 714 F6
592x592x292 2890 80 300-400 4.46 625 F7
592x592x292 2890 105 300-400 4.46 536 F8
592x592x292 2890 120 400-450 4.46 491 F9
287x592x292 1550 50 250-300 2.4 433 F5
287x592x292 1550 65 250-300 2.4 385 F6
287x592x292 1550 80 300-400 2.4 336 F7
287x592x292 1550 105 300-400 2.4 288 F8
287x592x292 1550 120 400-450 2.4 264 F9
490x592x292 2440 50 250-300 3.78 680 F5
490x592x292 2440 65 250-300 3.78 604 F6
490x592x292 2440 80 300-400 3.78 529 F7
490x592x292 2440 105 300-400 3.78 453 F8
490x592x292 2440 120 400-450 3.78 415 F9  

1. In case of specification and structure changes, the latest data provided by our company shall prevail

2. The company accepts orders for filters that are not specified in the table

More content URL: www.ecolead.cn Tel: 025-57138032