Burner with Movable platform & & Automobile. Door and also Style for Pets Person Cremation Organization

Style for Pets Cremation Business

Movable system & & Vehicle. Door

Independent Placement for Small Pet

Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business

Model

A1500

Image

Burning Rate

Average 150 kgs/hour

Feed Capacity

Standard 350 kgs/feeding

Primary Burning Chamber

1500 Liters

Secondary Burning Chamber

500 Litres

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

220V/380V

Gas Type

Diesel Oil/ All-natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 53.0 kg/hour

Gas Intake (Gas)

Average 63.6 m3n/hour

Inner Measurements

150 x 100 x 100cm (main chamber)

Exterior Measurements

240 x 170 x 380cm (without chimney)

Temperature Level Display

Yes

Oil Container Ability( if oil gas)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Smokeshaft Type

Stainless Steel

Devices Gross Weight

8000 kgs


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-26

50kgs/hr iraq general waste burner with 2 burning chambers

Items/Model

TS50M

Image

Melt Price

Typical 50 kg/hour

Feed Capability

Average 50-150 per feeding

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Combustion Chamber

450L

Internal Measurements

75x75x80cm

Additional Chamber

225L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5 Kw

Oil Usage (kg/hour)

Average 13.3

Gas Usage (N.G, m3n/Hour)

Average 16

Gas Consumption (L.P.G, m3n/Hour)

Typical 11.7

Temperature Level Display

4 Digital Display

Temperature Level Defense

Yes

Oil Storage Tank

100L

Feed Door

55x50cm

Chimney

8Meter

Smokeshaft Type

Stainless-steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

second. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

Outside Dimensions

175x120x140cm

Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS

Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS
K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core 

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

General requirements of a 100 kg/hr 3 combustion Chambers Burner

General specifications of a 100 kg/hr incinerator
No. Description Parameter value  
  model   HICLOVER YD100
1 Machine working mode Oil + Power Oil + Power
2 Voltage 220V C 3 phase or 1 phase 220V 1P
3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average 33Liters/hour/total incinerator 3 burners
6 Incineration rate 100 kg/hr = 400-600 kg/8hr average 100kgs per hour
7 Feed mode Manual manual
8 Primary combustion rate 1000 lit 1080 liters
9 Secondary combustion rate 240 lit 207 Liters
10 Tertiary combustion rate 416 lit 452 liters
11 Combustion chamber material High temp. resistant concrete High temp. resistant concrete
12 Internal dimensions (1st chamber) 100*100*100 cm (l*w*h) = 1000 lit 120*100*90cm(l*w*h) = 1080 lit
13 Internal dimensions (2nd  chamber) 40*40*150 cm = 240 lit Diameter 42*150cm=207 Liters
14 Internal dimensions (3rd  chamber) 40*40*260 cm = 416 lit Diameter 60*160cm=452 Liters
15 External dimensions 300*155*200 cm (l*w*h) 220*160*370 cm (l*w*h)
16 Door opening 90*90 cm 90*90 cm
17 Additional air fan 1 fan (on the door) 1 fan (on the door)
18 Fuel type Diesel oil/ Diesel oil
19 Burner Brand: Radiator or Hofmat Italy Baltur
20 Chimney length 3-4 meters 5 Meters
21 Chimney type and material H-type stainless steel, or High temp. resistant concrete 1 Meter High temp. resistant concrete +4 Meter Stainless steel
22 Smoke and smell filter Yes, two stages. Dry Scrubber 2 stages
23 Temperature monitor Yes, (for 1st and 3rd chambers) Yes, (all 3 chambers)
24 Temperature control Optional yes
25 Oil tank 500 lit needed. yes
26 Burning efficiency >98% yes
27 1st chamber temperature 300-700 oC 800-1000 oC
28 2nd chamber temperature 500-1000 oC 1000-1200 oC
29 3rd chamber temperature 800-1200 oC 1000-1300 oC
30 Smoke residency time >2 sec. >2 sec.
31 Gross weight 5-8 tons average 6.5 Ton
32 No. of Burners 3 3

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

DIESEL TERMINATED BURNER, WITH 1000 LTR FUEL TANK AND 6M CHIMNEY

Items/Model

TS250( PLC)

Photo

Concept

Waste Incineration Therapy

Burn Rate

Average 250 kg/hour

Feed Ability

Standard 400kg/feeding

Control Setting

PLC( Programmable Reasoning Controller Burner)

Combustion Chamber

2000L

Inner Measurements

210x88x110cm

Second Chamber

1000L

Smoke Filter Chamber

Yes

Feed Setting

Guidebook

Voltage

220V

Power

2.0 Kw

Oil Intake (kg/hour)

Typical 24.2( DO)

Gas Intake (m3/hour)

***

Temperature Display

Digital Present

Temperature Level Security

Yes

Oil Tank

1000L

Feed Door

2.04 x 1.06 M

Smokeshaft

3Meter

Chimney Kind

Stainless-steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

9000kg

External Measurements

3.00 mx1.60 mx3.00 m (without chimney)

INCINERATION IS A WASTE TREATMENT PROCESS THAT INVOLVES THE COMBUSTION OF ORGANIC SUBSTANCES CONTAINED IN WASTE MATERIALS. INCINERATION AND OTHER HIGH-TEMPERATURE WASTE TREATMENT SYSTEMS ARE DESCRIBED AS “THERMAL TREATMENT”. INCINERATION OF WASTE MATERIALS CONVERTS THE WASTE INTO ASH, FLUE GAS AND HEAT. THE ASH IS MOSTLY FORMED BY THE INORGANIC CONSTITUENTS OF THE WASTE AND MAY TAKE THE FORM OF SOLID LUMPS OR POWDER.

TWO (2) YEAR UPKEEP SPARES PLAN FOR LINE ITEM 2 X OIL DISCHARGED HEATER

2 X CEMENT FIXING PACKAGE (25KG)

2 X THERMOCOUPLE

2 X FIRE ROPE (1M)

2 X HT MASTIC (PER INCINERATOR)

1 X PPE PACKAGE


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

Incinerator with 1 or 3 area kind damp scrubber

Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour capacity.

Design

YD-150

Photo

Burning Price

Typical 150 kgs/hour

Feed Capability

Standard 300 kgs/feeding

Key Burning Chamber

1500 Liters

Additional Burning Chamber

500 Litres

Mix Burning Chamber

Yes

Smoke Filter Chamber

Damp Scrubber System( 3 Area Type)

Feed Setting

Manual

Voltage

380V

Power

9.0 Kw

Fuel Kind

Diesel Oil/ All-natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 24 kg/hour

Gas Intake (Gas)

***

Inner Dimensions

150 x 100 x 96cm (primary chamber)

Exterior Dimensions

240 x 170 x 380cm( without chimney/wet scrubber)

Temperature Monitor

Yes

Oil Tank Capacity( if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Kind

Stainless Steel

Equipment Gross Weight

11000 kgs

Procedure Technical Specs

Main Chamber Temperature Level

800 ℃–– -1000 ℃

Second Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

Mobile Containerized Waste Incinerators HICLOVER CA-200

Mobile Containerized Waste Incinerators pets or human cremation emergency use


Design

CA-200

Picture

Burning Rate

Typical 100 kgs/hour

Main Combustion Chamber

2000 Liters

Second Burning Chimney

Yes

Feed Setting

Manual

Voltage

220V

Power

3.0 Kw

Gas Kind

Diesel Oil

Burner

Italy Original

Oil Usage (Diesel Oil)

Average 53 kg/hour

Interior Measurements

200 x 100 x 100cm (main chamber)

Outside Measurements

290 x 200 x 170cm (key chamber)

Temperature Level Screen

Yes

Oil Tank Ability( if oil gas)

500 Liters

Door Opening

90 x 90cm

Smokeshaft Size

5.0 Meters

Chimney Kind

Stainless Steel

Tools Gross Weight

9000 kgs( with container)

Operation Technical Specifications

Paimary Chamber Temperature

800 ℃–– 1000 ℃

Additional Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Effectiveness

> 98%

Waste Lower Calorific Power

3000Kcal


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

Pet Dog Crematory HICLOVER A600

Model

A600, crematorium makers

Inner Measurements

130 x 70 x 65cm

Suit for Animal

Pet cat – – yes

– Pet dog – yes

Pig – no

Cow – – no

Key Item List

Primary Combustion Chamber

Additional Burning Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Situation

Chimney:5.0 Meters

*( upgrade to Stainless Steel, free price)

Italy oil/gas heater: 02 units

Oil Storage Tank (if oil gas): 200Liters

dog cremation urns

Design

A600

Photo

Feed Capability

Ordinary 30 kgs per feeding( animal)

Burning Rate

Typical 15 kgs per hour( animal)

Voltage

220V

Power

0.59 Kw

Gas

Gas or Diesel oil or LPG Gas

Burner

Italy Heater

Feed Setting

Handbook Feeding

Fuel usage (Oil)

10.0-16.0 Kgs/Hour

Gas usage (Gas)

10.0-15.0 m3/Hour

Exterior Dimensions

175 x 100 x 180cm (main body)

Internal Dimensions

130 x 70 x 65cm( Primary Chamber)

Waste combustion chamber

600Liters

Post Burning Chamber

200Liters

Oil Container Capacity

200 Litres or More( Optional)

Door Opening

50 x 60cm

Chimney

5.0 M or Even More( Optional)

Gross Weight

3300kgs

Chamber Product

Refractory Concrete

Max. Warm Value

160,000 Kcal/Hr.

Operation Technical Specs

Solid Chamber temperature

8000C -10000 C

Concentration camp temperature

10000C -12000 C

Chamber Anti-Rate

14500C

Residency time

2.0 Sec.

Burning performance

> 97%

Waste Lower Calorific Power

3000Kcal

small incinerator for sale
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

Waste Incineration Therapy BURNING PRICE: 100-150kgs per hr HICLOVER TS150

BURNING RATE: -100 -150 kgs per hour

MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING)

MAX OPERATING TEMPERATURE LEVEL: 1000-1200 oC (AFTER HEATER BURNING)

SECONDARY MELTING CAPABILITY: COMPULSORY

DENSITY INSULATION: 50 mm high

Refractory capability: minutes 114mm

STURDY REFRACTING LINING TO WITHSATND 17500C

AVEARGE BURN OUT TIME: MAXIMUM 3HRS

GAS TYPE: FUEL OIL (DIESEL)

FUEL INTAKE IN LTRS/HR: average 14

RESIDNECY TIME IN SECONDARY CHAMBER: 2 PHASES

Items/Model

TS150( PLC)

Photo

Concept

Waste Incineration Treatment

Burn Price

Standard 100-150 kg/hour

Feed Capability

Standard 750kg/feeding

Control Setting

PLC( Programmable Reasoning Controller Incinerator)

Chamber Material

High Alumina Fire Brick Wall, 1750 ℃ Rate

Paint for outdoors face

800 ° C Price

Burning Chamber

1570L

Inner Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Guidebook

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Consumption (Liter/hour)

Ordinary 14( D.O)

Gas Intake (m3/hour)

***

Temperature Screen

Digital Show

Temperature Level Defense

Yes

Oil Tank

2000L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x280cm( without chimney)



HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28

HICLOVER Burner mobile little With Wheel as well as Brake

Version

YD-30 Mobile Type

Photo

Burning Rate

Average 30 kgs/hour

Feed Ability

Typical 60 kgs/feeding

Chamber Text

Stainless Steel

Mobile Feature

With Wheel and also Brake

Primary Burning Chamber

280 Liters

Secondary Combustion Chamber

150 Litres

Mix Burning Chamber

Yes

Feed Setting

Handbook

Voltage

220V

Power

1.5 Kw

Gas Kind

Diesel Oil

Burner

Italy Original

Oil Intake (Diesel Oil)

Standard 13.3 kg/hour

Inner Dimensions

80 x 60 x 60cm (main chamber)

Exterior Dimensions

125 x 90 x 260cm (without smokeshaft)

Temperature Level Display

Yes

Oil Container Capacity( if oil fuel)

100 Litres

Door Opening

50 x 50cm

Smokeshaft Size

2.0 Meters

Chimney Type

Stainless-steel

Equipment Gross Weight

1600 kgs

Operation Technical Specifications

Key Chamber Temperature

800 ℃–– -1000 ℃

Secondary Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Effectiveness

> 98%

Waste Lower Calorific Power

3000Kcal


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28