double chamber incinerator

Waste calorific value : 4000KCAL/KG
Moisture Content : 10-25%
Nominal Capacity : 50Kg/Hour batch load
Secondary Chamber : 2 Seconds @ 850degrees C
The primary combustion chamber must ensure minimum exit temperature is not less than 850 degrees C.

INSULATION
Calcium Silicate
Limiting Continuous service limit 1000 degrees C.
Thickness 25mm

THROUGHPUT
50kg/hour at a nominal calorific value of 4,000 kcal/kg and an average bulk density of 120kg/MCubed for general waste and 160kg/MCubed for health care waste.All types of chemicals substances (Biocides) that utilized for Oil operation sites (water base Drilling, oil operating facilities for the corrosion and others: The examples of the biocides are “WS-36, HAI-85M, SODA ASH, DSMA, MICRO MATRIX, CALCIUM CARBONATE FINE, BARAKLEAN, GILSONITE, MIXED WASTE SOIL CHEMICALS, ZINC CARBONATE, CAUSTIC SODA, ENVIROTHIN, BARAZAN D,..etc) as well as the substances are liquid and solid.

2. In regards to the quantity of burning the waste, it could be 200 – 500 kg per hour.

3. Our Operational time can be in Day and can be at night.

4. Can you please give me the cost of unit operated with Diesel  and Gas.The primary combustion chamber is the main structure of the incinerator, fabricated from mild steel plate and stiffened with rolled steel sections. It is carried from the floor level on a substantial steel support frame. Internally the shell is lined with calcium silicate insulation and a hot face combination of super duty brickwork or high strength castable.
The primary combustion chamber must ensure minimum exit temperature is not less than 850°C.
One Manual Load Incinerator comprising:
·???????? Manual Loading door
·???????? Horizontal solid hearth, refractory lined primary combustion chamber. Approximate dimensions 800 mm diameters x 2100mm long
·???????? Full sized bulk load/ash removal door
·???????? 1 off diesel-fired ignition burner — temperature controlled
·???????? 1 off combustion air supply fan and distribution system, automatic control
·???????? High capacity secondary combustion chamber with residence time not less than 2 seconds @ >850°C
·???????? 1 off diesel-fired afterburner — temperature controlled
·???????? Control panel — automatic operation
e????? Temperature indication primary and secondary chambers 0-1200°C
e????? Refractory lined flanged chimney to a height of 10M above ground level

Light Weight Small-Scale Medical, Mobile Optional Type

Light Weight Small-Scale Medical, Mobile Optional Type


Model YD-30 
Picture

 
Burning Rate  average 30 kgs/hour
Feed Capacity average 40 kgs
Paimary Combustion Chamber 200 Liters
Secondary Combustion Chamber 100 Liters
Mix Combustion Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.59Kw
Fuel Type Diesel Oil
Burner Italy Original
Oil Consumption (Diesel Oil) average 13.3 kg/hour
Gas Consumption (Natural Gas) ***
Internal Dimensions 80 x 50 x 50cm (primary chamber)
External Dimensions 125 x 90 x 180cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 60 Liters
Door Opening 40 x 40cm
Chimney Length 1.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 1500 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800–1000
Secondary Chamber Temperature 1000-1200
Residency Time 2.0 Sec.
Burning Efficiency 98%
Waste Lower Calorific Power 3000Kcal
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-26

SOLID WASTE INCINERATOR

Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal.

Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an innovative low emissivity protective coating. bio medical waste treatment plant ( Incineration )with panel.

SOLID WASTE INCINERATOR    Feeding Capacity:    200 to 220 Kg.
Burn Rate *    60 Kg / hr
Ingredients to be burned    Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc.
Chambers *    Dual Chamber.
1: Primary Controlled Air
2: Secondary Excess Air
Temperature Monitoring    Required
Temperature Control to Primary & Secondary Chambers    Required
System Status & Alarms    Required for all necessary parameters.
Fittings & Accessories    Complete Package is required ( Including Nozzles & Flanges etc.)
Installation Requirements.    As low as possible . Almost Plug & Play type.
Dimensional Sketch, Operation & Installation Manuals.    Required
Off – Gas System    Required
Heat Insulation    Required for indoor installation
Delivery    Karachi Sea Port – Pakistan

The details of Components of incinerator is as follows:
Component Name        Features                 Range.
Primary Chamber    Temperature Required*    800 – 1000 deg C.
Heating Source    Natural Gas

Secondary Chamber    Temperature *    1100 – 1300 deg. C
Heating Source    Natural Gas + Propane or Fuel Oil as an additional source
Off – Gas Residence Time     2 Seconds.
Refractory Material    Material *    Alumina ( 56 – 80 % Pure )
Lining *    SS 316L
Life Span *    10 – 15 years.
Rating Temperature    1600 – 1800 deg. C
Media    Slightly acidic
Insulation    Material    Ceramic Fiber
Thickness    25 “ minimum
Feeding & Ash Removing     System    Air Tight ventilating locked doors ( Feeding from Top will be preferred)
Spares    Required for 5 Years trouble free operation

Small Scale Medical Waste Coronovirus (Covid 19) Incinerator 30 kgs per hour Model TS30 PLC Auto Control

Items/Model

TS30(PLC)

Picture

 

Burn Rate

Average 30 kg/hour

Feed Capacity

Average 60kg per feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Auto Control and Display

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

Average 13.3

Gas Consumption (N.G, m3n/Hour)

Average 16

Gas Consumption (L.P.G, m3n/Hour)

Average 11.7

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

55x50cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

3000kgs/4000kgs

External Dimensions

175x120x140cm


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-26

CONTAINERIZED INCINERATOR FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES

CONTAINERIZED INCINERATOR FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES (BOTH DOMESTIC AND INDUSTRIAL) AT A MINIMUM RATE OF 300KG/HR WITH THE FOLLOWING SPECIFICATIONS:

Ø  PRIMARY CHAMBER VOLUME 7.2M³

Ø  BURNING CAPACITY 300Kgs/hr.

Ø  PRIMARY CHAMBER TEMPERATURE 850⁰C AND SECONDARY CHAMBER TEMPERATURE 1100⁰C

Ø  REFRACTORY THICKNESS 225MM; REFRACTORY WITHSTAND TEMPERATURE 1400⁰C

Ø  RAM LOADER CAPACITY 0.75M³; OPERATIONAL CYCLES PER DAY 8-16 Hrs.

Ø  FUEL DIESEL/NATURAL GAS; NUMBER OF PRIMARY BURNERS & RATING: 2 @ 250kw

Ø  NUMBER OF SECONDARY BURNERS & RATING: 2 @ 400kw; ELECTRICAL SUPPLY 230V 60Hz

Ø  BIN TIPPER, MONITORING SYSTEM, CLEANING SYSTEM

Ø  GAS CLEANING AND GAS MONITORING.MSW1000 General Medical Waste Incinerators burn rate up to 100kg/hr
A2400 Animal / poultry Waste Incinerators burn rate up to 200kg/hr.Laboratory  waste Management  system
01. Liqued water purification system.
02. Number of laboratories    – 05
03. The estimated liquid water waste    – 6000 L including
a. chemicals
b. toxins
c. Bio Hazardous materials.
Temporary allocated space for purifications system- 30×20
The following should be indicating in the biding document
1.Method of disposing treated waste water
2.Method of discarding the sludge
3.To follow ISO standard/regulations of Central Environment Authority[CEA]
4.Time frame for construction
5.Request the cost for each item of the project [Consultancy/designing/construction] as well for the whole project.
6.Warranty period and maintaincne.

Three Combustion Chambers MEDICAL WASTE INCINERATOR

Model

WS-35

Picture

Burning Rate

Average 35 kgs/hour

Feed Capacity

Average 80 kgs

Primary Combustion Chamber

460 Liters

Secondary Combustion Chamber

200 Liters

Third Combustion Chamber

200 Liters

Smoke Filter Chamber

Wet Scrubber System

Feed Mode

Manual

Voltage

220V

Power

2Kw

Fuel Type

Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

***

Gas Consumption (Natural Gas)

Average 24 m3n/hour

Internal Dimensions

110 x 70 x 60cm (primary chamber)

External Dimensions

160 x 100 x 180cm (without wet scrubber)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

***

Door Opening

50 x 50cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

5000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800–-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal

Primary chamber:
Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature 

sensor points with complete internal fans.
Secondary Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 

02 Sec gas residence times.
Third Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal 

fans. 02 Sec gas residence time.

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-25

Containerized Type Pre-Assembled Mobile Hospital Waste Incinerator Model CA100

Items/Model

CA100

Picture

Principle

Medical Waste Incineration Treatment

Burn Rate

Average 100 kg/hour

Feed Capacity

Average 200kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

1.3 Kw

Oil Consumption (kg/hour)

Average 20.4 Kgs/Hour

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-25

dispose Medical waste IV

the incinerator can be used to dispose  Medical waste IV, used needles, used syringes, scalpels, used dressing material ,personal protective equipments like gown, gloves etc. amputated body parts, excreta from patients and other laboratory waste.incineration units that can handle a mix of medical and hazardous wastes. The medical wastes include (but are not limited to) materials contaminated with blood, bodily fluids, fecal matter, and human tissue/organs from surgery. The hazardous compounds include (but are not limited to): xylene, toluene, chloroform, methylene chloride, trichloroethylene, acetonitrile, formaldehyde wastes, chemotherapy wastes (e.g., Chlorambucil, Cytoxin, Daunomycin, etc.) radiology wastes (e.g., glutaraldehyde), and mercury-containing compounds.includes amputated body parts, body fluids including contaminated blood, blood products, excreta from patients, cultures of contagious viruses and other laboratory wastes e.t.c.
Medical might also include used needles, used syringes, used , expired or contaminated dressing materials like bandages, plasters and plastics, e.t.c. The Incinerators should also allow for disposal of other wastes generated in hospital environment.Technical Specifications for Portable Incinerators

The Chamber volume of approximately 0.37m3 and a
1     combustible load volume (volume of material) of
approximately 0.30 m3

2     Burner power of approximately 189,000kcal/hour
Maximum Combustion Temperature of up to 1250

Degree Celsius
Type of emitted Gas: Inert and nil environmental pollution effect
Electrical Power: 220V/50 or 60 Hertz

Fuel: Diesel

Electrical consumption of approximately: 0.35 kw/hr

Fuel consumption range: 7 – 11 ltrs/hr

Controls: Incinerator control including control panel, timer, display for monitoring combustion temperature, system error display, etc.
Packaging/Installation: Incinerator fully assembled and ready to be plugged in power source

Instruction manual: Package must be provided with instruction manual including detailed information to installation, operation, maintenance, interpretation of trouble shooting signals and contact telephones
numbers/emails of local or overseas manufacturer’s technicians that can be contacted for guidance on operation of the equipment, if necessary.

training guide/manual on a compact disc including a demonstration for installation, operation and
maintenance, as well as safety guidelines, etc.

Scope of Supply: Package must be provided including
all the required accessories for installation and must
include spare parts/consumables that are required for a
one year period at a combustion rate of up to 8 hours
daily

Warranty must be provided for a 5-years period
starting with the incinerator’s installation and
including the provision of accessories and
consumables

Containerized Mobile Incinerator Medical Waste Incinerator Model CA50

HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50


Model

CA50

Picture

Waste Treatment

Medical Waste Incineration Treatment

Feed Capacity

Average 100 kgs per feeding

Burning Rate

Average 50 kgs per hour

Burning Time per Feed

Average 2 hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Temperature Monitor

Digital Display

Fuel consumption (Oil)

Average 16.9 Kgs/Hour

Internal Dimensions

100x80x70cm (Primary Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Post Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Chimney

5.0M

Gross Weight

4500kgs

Chamber Material

Firebrick ,Refractory Concrete

Max. Heat Value

166,000Kcal/Hr.

Operation Technical Specifications

Solid Chamber temperature

8000C -10000C

Gas Chamber temperature

10000C -12000C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-24

WASTE CATALOGUE AND HAZARDOUS WASTE LIST

1 Incinerator 30 =KG  burn/h and it must have a Scrubber.

2 Incinerator must have Electrical Plastic Shredder for cutting of glass bottle,surange of Medicine.

3 Incinerator must have Electrical Auto Clave or Microwave for Dis Infection  separately with incinerator.
4 Incinerator must have Double Chambers first Chamber must gave 800C temperature and secondary Chamber working 1200C temperature.
5 Incinerator in out place must have a Parameter to show inner temperature of incinerator.
6 Incinerator must work in two systems Electric and fuel describe in which kind of fuel works.
Note we want it works on diesel fuel and electric also.for a small pig slaughterhouse project in Vietnam we are looking for a
solution to destroy safely inedible  and seized animal products.

As the slaughtered pigs are consumed by more than 90% (from hooves to
head, blood, etc) the waste volume is quite small even in
slaughter-points with up to 100 slaughtered pigs per day.

Although the use of meat and bone meal is not prohibited in Vietnam the
small volumes of waste do not seem to justify the installation of a
rendering unit, not even of a batch cooker, so incineration seems to be
the best option.

I would like to receive more technical details e.g. fuel consumption for
incinerating 100/200 kg of animal products per day and also the FOB
price of the unit.The types of waste to be treated are (after EUROPEAN WASTE CATALOGUE AND HAZARDOUS WASTE LIST, 2002):

18 01 01 sharps (except 18 01 03)

18 01 02 body parts and organs including blood bags and blood preserves (except 18 01 03)

18 01 03* wastes whose collection and disposal is subject to special requirements in order to prevent infection

18 01 04 wastes whose collection and disposal is not subject to special requirements in order to prevent infection (for example dressings, plaster casts, linen, disposable clothing, diapers)

18 01 06* chemicals consisting of or containing dangerous substances

18 01 07 chemicals other than those mentioned in 18 01 06

18 01 08* cytotoxic and cytostatic medicines

18 01 09 medicines other than those mentioned in 18 01 08

18 01 10* amalgam waste from dental care