Items/Model
TS100( PLC)
Photo
Concept
Waste Incineration Treatment
Burn Price
60-80 kg/hour
Control Mode
PLC( Programmable Reasoning Controller Incinerator)
Combustion Chamber
1200L
Interior Measurements
120x100x100cm
Second Chamber
600L
Smoke Filter Chamber
Yes( Dry Scrubber)
Feed Setting
Manual
Voltage
220V
Oil Consumption (kg/hour)
Typical 20.4
Gas Intake (m3/hour)
***
Temperature Monitor
Digital Present
Temperature Level Defense
Yes
Oil Container
1100L
Feed Door
80x60cm
Smokeshaft
10Meter
Chimney Kind
Stainless Steel
1st. Chamber Temperature
800 ℃– -1000 ℃
second. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
6000kg
External Dimensions
260x150x180cm
The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using dieselfuel as a supplemental fuel oil.It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapiddeployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are severalvariations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 yearsif the specified maintenance schedule is followed.The incinerators should be supplied assembled, whenever possible, and all parts and components should bepackaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130)and via sea in a 20’ ISO sea shipping containers.HICLOVER – Medical EnvironmentalWaste IncineratorsMedical Waste IncineratorPet Animal CremationSolid Waste Incinerator
Tel: +86-25-8461 0201Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]Nanjing Clover Medical Technology Co.,Ltd.2020-03-21
Aug, 2025
Plus Size Burning Price : 150-200 kg/hr Solid Waste Devices Primary and Second Combustion Chamber Burner
Items/Model
TS500( PLC)
Picture
Concept
Waste Incineration Treatment
Burn Price
150-200 kg/hour
Control Setting
PLC( Programmable Logic Controller Burner)
Combustion Chamber
2700L
Interior Dimensions
190x120x120cm
Second Chamber
1300L
Smoke Filter Chamber
Yes
Feed Mode
Handbook
Voltage
220V
Oil Intake (kg/hour)
Ordinary 28
Gas Usage (m3/hour)
***
Temperature Display
Digital Display
Temperature Security
Yes
Oil Tank
1400L
Feed Door
90x80cm
Chimney
10Meter
Smokeshaft Kind
Stainless Steel
1st. Chamber Temperature
800 ℃– -1000 ℃
2nd. Chamber Temperature
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
15000kg
Outside Measurements
400x210x300cm( without chimney)
The air supply should be controlled efficiently;Flame contact with all the gases should be achieved;The minimum combustion temperature of the primary chamber should not be less than 850°C;The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.The following conditions should be met in the secondary combustion chamber:The air supply should be controlled efficiently;Flame contact with all the gases should be achieved;The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;HICLOVER – Medical EnvironmentalWaste IncineratorsMedical Waste IncineratorPet Animal CremationSolid Waste Incinerator
Tel: +86-25-8461 0201Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]Nanjing Clover Medical Technology Co.,Ltd.2020-03-21
Aug, 2025
Mobile Cremation Devices
Design
CA-200
Image
Burning Rate
Ordinary 100 kgs/hour
Key Burning Chamber
2000 Liters
Additional Burning Smokeshaft
Yes
Feed Mode
Guidebook
Voltage
220V
Power
3.0 Kw
Fuel Kind
Diesel Oil
Burner
Italy Original
Oil Usage (Diesel Oil)
Typical 53 kg/hour
Interior Dimensions
230 x 100 x 90cm (primary chamber)
External Measurements
290 x 200 x 170cm (key chamber)
Temperature Monitor
Yes
Oil Container Capacity( if oil fuel)
500 Liters
Door Opening
90 x 90cm
Smokeshaft Size
5.0 Meters
Chimney Type
Stainless Steel
Devices Gross Weight
9000 kgs( with container)
Procedure Technical Specifications
Paimary Chamber Temperature
800 ℃–– 1000 ℃
Second Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Burning Efficiency
> 98%
Waste Lower Calorific Power
3000Kcal
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-03-22
Aug, 2025
Incinerator for medical facility waste monitoring
Burner for healthcare facility waste monitoring with the adhering to attributes:
– In high temperatures (pyrolytic burner 2 chambers with temperatures ranging from 950 º C to 1320 º C;
– Capacity to damage of 400 to 600kg per hr;
– Efficient in destroying microbes;
– Drain ash;
– Drain needle as well as glass crusher;
– Patio with tap water for hand cleaning and decontamination;
– Observe the problem of environmental top quality criteria, discharges fluent as well as policy on the issue of waste; mount large incinerator to among the largest veterinary health center in KSA so if you will certainly support us with one system (large incinerator) and ecological with onsite training, the ability for the device is 2000 Kg for cattle, equines and also farm animals additionally suitable to all animal waste kinds, we require it diesel fired. OES-Industrial MultiWaste Incinerator System (Solid/Liquid)
Extent of the Job:
Style, setup as well as commissioning of multi hazardous waste burner.
Capability: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with double chamber system).
1st chamber-870 Deg.C – – 900 Deg.C.
2nd chamber-1000 deg.C– 1200 Deg.C
Resources Of The Wastes.
The following types of wastes can be dealt with by using incinerator.
a). biography medical waste/pharmaceutical waste.
b). strong chemical waste/textile markets waste.
c). liquid chemical waste.
d). dyes as well as intermediate waste.
e). natural chemical waste.
f). liquid ink waste/acidic deposit.
g). insecticides/herbicides/pesticides.
h). fungicide waste.
i). ethanolamine.
j). amino ethanol.
k). mono ethanolamine.
l). ETA, MEA waste.
m). wastes after treatment of chemicals in etp plant.
n). blended alcohol waste water.
o). alcoholic waste.
p). farming liquid chemical waste.
q). sludge mix liquid.
r). slurry/adhesive/grease/ powder finish wastes.
s). semi strong liquid chemical waste.
t). bulk completely dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass grains.
w). utilized tires.
x). used cotton cloths.
y). contaminated plastics/resin wastes.
Range of Work:.
Incinerate all types of liquid/solid hazardous/chemical/non contaminateds materials avaliable in the industries with appropriate scrubbing up system with common emission rates.
The twin stage incinerator aids to burn the waste in 2 stages, initially at a medium temperature of 870- 900 Deg C and also the 2nd stage at 1200 deg C.
Producing ash as well as Aeriform fumes which are treated with cyclone type damp scrubber as well as caustic scrubber to generate air with contaminants in the allowed variety as well as Non dangerous ash mainly not natural salts.
Incinerator utilities.
Burner should have complying with requirements:.
Metallic seal framework with ceramic insulation to stay clear of warm radiation and also control glowing temperature level.
Advanced gas treatment system to avoid emission of hazardous gases (rubbing system).
Reduced intake high performance compact automated burning system.
Low running and upkeep prices.
Fully automatic and also easy to operate control board.
Afterburner Preheat.
Thick refractory concrete lining ranked at 1600 C.
Solid Hearth to enable maximum Fatigue.
Large Leading opening cover for simple loading.
Wide door for ash removal.
Optional Stainless Steel Case.
Warmth recovery option
Aug, 2025
Medical Facility Waste Monitoring
Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description Minimum Requirements
Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control
Description of the Chimney Top mounted, self supporting
Incinerator performance 150kg/hr
Refuse Hospital waste and carcasses
Recommended Temperatures Minimum 1000⁰C
Dimensions:
Length
Width
Height
Extra width for burners At least 3000mm
Loading door opening Minimum 700mm x 600mm
Hearth area 5.00square meters
Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume At least 3 cubic meters
Mixing chamber volume At least 1 cubic meters
Settling chamber volume At least 3 cubic meters
Weight excluding chimney 15, 000kg at manufacture
Firing tools supplied Hoe, Poker and rakeMaterial of construction Case – 5mm mild steel.
Bracing – Heavy angle and channel.
Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Ashing door – High grade cast iron.
Loading door – 5mm mild steel lined with 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory concrete:
Alumina content of refractory
Refractory thickness
Minimum 49%
At least 127mm.
Insulation to walls 1000⁰C Castable insulation
Chimney stack:
Chimney
Height from base 3.5 mm mild steel
9 meters above ground level and clear the highest point of the building by not less than 3 meters
At least 560mm
At least 750Kg
Controls:
Draught
Air supply
Electric
Barometric indicator, door operated draught limiter
Built-in forced heated air ducts, primary and secondary (intensifier)
Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required 415 Volts Three phase.
Auxiliary fuel Electrically operated only
Emission Multiple chamber design with inbuilt emission control
Paint: Case and stack 400⁰C Heat Resistant Grey
Temperature of case 100⁰C
Aug, 2025
WASTE BROCHURES As Well As CONTAMINATED MATERIALS LIST
1 Burner 30 =KG burn/h and also it need to have a Scrubber.
2 Burner should have Electric Plastic Shredder for cutting of glass container, surange of Medication.
3 Burner need to have Electrical Car Clave or Microwave for Dis Infection independently with burner.
4 Incinerator needs to have Double Chambers initially Chamber should provided 800C temperature level as well as additional Chamber working 1200C temperature level.
5 Incinerator in out place must have a Specification to show internal temperature level of incinerator.
6 Burner has to operate in 2 systems Electric and also fuel explain in which type of fuel jobs.
Note we want it works on gasoline and also electrical also.for a small pig slaughterhouse task in Vietnam we are looking for a.
solution to ruin securely inedible and confiscated pet items.
As the slaughtered pigs are consumed by more than 90% (from hooves to.
head, blood, etc) the waste volume is fairly tiny also in.
slaughter-points with as much as 100 slaughtered pigs each day.
Although using meat and also bone meal is not banned in Vietnam the.
small quantities of waste do not seem to warrant the installment of a.
rendering system, not also of a batch stove, so incineration seems to be.
the very best option.
I wish to get even more technological details e.g. gas usage for.
blazing 100/200 kg of animal items per day as well as also the FOB.
cost of the unit.The types of waste to be treated are (after EUROPEAN WASTE BROCHURE AND CONTAMINATED MATERIALS CHECKLIST, 2002):
18 01 01 sharps (other than 18 01 03)
18 01 02 body components and organs including blood bags and also blood maintains (other than 18 01 03)
18 01 03 * wastes whose collection and also disposal undergoes special needs in order to avoid infection
18 01 04 wastes whose collection as well as disposal is not subject to unique requirements in order to protect against infection (for example dressings, cast, linen, disposable clothes, baby diapers)
18 01 06 * chemicals containing or consisting of unsafe compounds
18 01 07 chemicals besides those stated in 18 01 06
18 01 08 * cytotoxic as well as cytostatic medications
18 01 09 medications aside from those discussed in 18 01 08
18 01 10 * amalgam waste from dental treatment
Aug, 2025
dispose Medical waste IV
the incinerator can be made use of to get rid of Medical waste IV, used needles, made use of syringes, scalpels, used dressing material, individual safety devices like gown, gloves and so on truncated body parts, excreta from clients and also various other research laboratory waste.incineration devices that can handle a mix of clinical as well as contaminateds materials. The clinical wastes consist of (yet are not limited to) materials contaminated with blood, physical liquids, feces, and also human tissue/organs from surgical treatment. The dangerous compounds include (however are not limited to): xylene, toluene, chloroform, methylene chloride, trichloroethylene, acetonitrile, formaldehyde wastes, radiation treatment wastes (e.g., Chlorambucil, Cytoxin, Daunomycin, and so on) radiology wastes (e.g., glutaraldehyde), and mercury-containing compounds.includes amputated body parts, body fluids including contaminated blood, blood items, excreta from people, cultures of transmittable infections as well as various other research laboratory wastes e.t.c.
Medical might also consist of used needles, made use of syringes, made use of, expired or infected clothing products like plasters, plasters and plastics, e.t.c. The Burners ought to likewise enable disposal of other wastes created in healthcare facility environment.Technical Requirements for Portable Incinerators
The Chamber volume of around 0.37 m3 and also a.
1 combustible lots quantity (quantity of material) of.
around 0.30 m3
2 Burner power of around 189,000 kcal/hour.
Optimum Burning Temperature Level of approximately 1250
Degree Celsius.
Kind of sent out Gas: Inert as well as zero ecological air pollution effect.
Electric Power: 220V/50 or 60 Hertz
Fuel: Diesel
Electric intake of roughly: 0.35 kw/hr
Gas usage variety: 7 – – 11 ltrs/hr
Controls: Incinerator control including control panel, timer, display screen for keeping an eye on combustion temperature level, system mistake display screen, and so on
. Packaging/Installation: Burner completely set up as well as all set to be connected in power source
User’s manual: Bundle has to be given with user’s manual including described information to installment, procedure, upkeep, analysis of problem shooting signals and also contact telephones. numbers/emails of neighborhood or abroad supplier’s specialists that can be called for assistance on procedure of the devices, if required.
training guide/manual on a compact disc including a demonstration for installment, operation and also. maintenance, in addition to safety standards, etc.
Scope of Supply: Bundle needs to be supplied including. all the called for devices for installation and also must. consist of spare parts/consumables that are needed for a. one year period at a burning rate of approximately 8 hrs. daily
Guarantee must be provided for a 5-years period. beginning with the burner’s setup and. consisting of the arrangement of accessories as well as.
consumables
Aug, 2025
CONTAINERIZED BURNER FOR INCINERATING HAZARDOUS AND ALSO NON HAZARDOUS WASTES
CONTAINERIZED BURNER FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES (BOTH DOMESTIC As Well As INDUSTRIAL) AT A MINIMUM PRICE OF 300KG/HR WITH THE COMPLYING WITH REQUIREMENTS:
Ø PRIMARY CHAMBER VOLUME 7.2 M ³
Ø BURNING CAPACITY 300Kgs/hr.
Ø PRIMARY CHAMBER TEMPERATURE 850 ⁰ C AND SECONDARY CHAMBER TEMPERATURE LEVEL 1100 ⁰ C
Ø REFRACTORY DENSITY 225MM; REFRACTORY WITHSTAND TEMPERATURE 1400 ⁰ C
Ø RAM LOADER CAPACITY 0.75 M ³; FUNCTIONAL CYCLES EACH DAY 8-16 Humans resources.
Ø GAS DIESEL/NATURAL GAS; VARIETY OF PRIMARY BURNERS & & SCORE: 2 @ 250kw
Ø VARIETY OF SECONDARY BURNERS & & RANKING: 2 @ 400kw; ELECTRIC SUPPLY 230V 60Hz
Ø CONTAINER TIPPER, MONITORING SYSTEM, CLEANSING SYSTEM
Ø GAS CLEANING AND ALSO GAS MONITORING.MSW1000 General Medical Waste Incinerators melt price approximately 100kg/hr
A2400 Animal/ fowl Waste Incinerators burn rate as much as 200kg/hr. Laboratory waste Management system
01. Liqued water filtration system.
02. Number of laboratories – 05
03. The approximated liquid water waste – 6000 L including
a. chemicals
b. contaminants
c. Bio Hazardous products.
Temporary alloted room for filtrations system- 30×× 20.
The following need to be indicating in the biding document.
1. Technique of getting rid of treated waste water.
2. Method of disposing of the sludge.
3. To comply with ISO standard/regulations of Central Environment Authority [CEA] 4. Period for building and construction.
5. Request the cost for every thing of the project [Consultancy/designing/construction] For the whole task.
6. Guarantee period as well as maintaincne.
Aug, 2025
STRONG WASTE INCINERATOR
Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal.
Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an innovative low emissivity protective coating. bio medical waste treatment plant ( Incineration )with panel.
SOLID WASTE INCINERATOR Feeding Capacity: 200 to 220 Kg.
Burn Rate * 60 Kg / hr
Ingredients to be burned Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc.
Chambers * Dual Chamber.
1: Primary Controlled Air
2: Secondary Excess Air
Temperature Monitoring Required
Temperature Control to Primary & Secondary Chambers Required
System Status & Alarms Required for all necessary parameters.
Fittings & Accessories Complete Package is required ( Including Nozzles & Flanges etc.)
Installation Requirements. As low as possible . Almost Plug & Play type.
Dimensional Sketch, Operation & Installation Manuals. Required
Off – Gas System Required
Heat Insulation Required for indoor installation
Delivery Karachi Sea Port – Pakistan
The details of Components of incinerator is as follows:
Component Name Features Range.
Primary Chamber Temperature Required* 800 – 1000 deg C.
Heating Source Natural Gas
Secondary Chamber Temperature * 1100 – 1300 deg. C
Heating Source Natural Gas + Propane or Fuel Oil as an additional source
Off – Gas Residence Time 2 Seconds.
Refractory Material Material * Alumina ( 56 – 80 % Pure )
Lining * SS 316L
Life Span * 10 – 15 years.
Rating Temperature 1600 – 1800 deg. C
Media Slightly acidic
Insulation Material Ceramic Fiber
Thickness 25 “ minimum
Feeding & Ash Removing System Air Tight ventilating locked doors ( Feeding from Top will be preferred)
Spares Required for 5 Years trouble free operation
Aug, 2025
dual chamber incinerator
Waste calorific value: 4000KCAL/KG
Wetness Web content: 10-25%.
Nominal Capability: 50Kg/Hour batch load.
Secondary Chamber: 2 Secs @ 850degrees C.
The main combustion chamber should ensure minimal departure temperature level is not less than 850 degrees C.
INSULATION.
Calcium Silicate.
Restricting Continuous service restriction 1000 degrees C.
Thickness 25mm
THROUGHPUT.
50kg/hour at a small calorific worth of 4,000 kcal/kg as well as an average bulk thickness of 120kg/MCubed for basic waste and 160kg/MCubed for healthcare waste.All sorts of chemicals compounds (Biocides) that made use of for Oil procedure sites (water base Drilling, oil operating facilities for the corrosion and also others: The instances of the biocides are “WS-36, HAI-85M, SOFT DRINK ASH, DSMA, MICRO MATRIX, CALCIUM CARBONATE PENALTY, BARAKLEAN, GILSONITE, MIXED WASTE DIRT CHEMICALS, ZINC CARBONATE, CAUSTIC SOFT DRINK, ENVIROTHIN, BARAZAN D,. etc) as well as the materials are fluid and strong.
2. In regards to the amount of shedding the waste, maybe 200 – – 500 kg per hr.
3. Our Operational time can be in Day as well as can be at night.
4. Can you please provide me the expense of device operated with Diesel and Gas.The primary combustion chamber is the major structure of the burner, produced from light steel plate and stiffened with rolled steel sections. It is carried from the floor level on a significant steel support structure. Internally the covering is lined with calcium silicate insulation and also a warm face combination of incredibly duty brickwork or high strength castable.
The key burning chamber should make sure minimum departure temperature level is not much less than 850 ° C
. One Hands-on Lots Incinerator making up:.
·???????? Guidebook Loading door.
·???????? Horizontal strong fireplace, refractory lined main combustion chamber. Approximate dimensions 800 mm sizes x 2100mm long.
·???????? Complete sized bulk load/ash elimination door.
·???????? 1 off diesel-fired ignition heater– temperature managed.
·???????? 1 off burning air supply follower as well as distribution system, automated control.
·???????? High capability additional burning chamber with residence time not much less than 2 secs @ >> 850 ° C. ·???????? 1 off diesel-fired afterburner– temperature managed.
·???????? Control panel– automated operation.
e????? Temperature indicator key and also secondary chambers 0-1200 ° C.
e????? Refractory lined flanged smokeshaft to a height of 10M over ground degree