incinerator manufacturers china

  1. Ash should be only 5% of the waste material

 

  1. Weight of Incinerator – 50-60 Kg

Municipal incinerators with a 10-metric ton/24-hour capacity, complete with Stacks, control panels and all accessories,

complying with 01015 par. 5.16.1

LOT

2.0

 

Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks,

control panels and all accessories

 

 

  1. 220V AC

 

  1. Surgical , medical & laboratory waste

 

 

  1. PRODUCT DIMENSIONS

 

Description   Dimensions

Destructive capacity  30 Kg / hour

Operation     12h/24, 6d / 7

Fuel       diesel oil

Chimney       Height: 5m, Diameter: 280mm

Volume of combustion

 

chamber Combustion: 0.3 m3

Post combustion: 0.2m3

Mixed combustion chamber: 0.3m3

` TEMPERATURES:

. Combustion

. Afterburner

900 ° C

1100 ° C

POWER BURNER

Combustion

Afterburner

 

0.11 KW

0.11 KW0

 

Fan power    0.37 kW

medical waste incinerators manufacturers

chemical agents to be utilized:
10% heptyl (unsymmetrical dimethylhydrazine) water solution,
heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration,
10% azotic (nitric) acid water solution,
azotic (nitric) acid vapour with concentration up to 1.1 kg/m3;
2.    neutralization method: thermal decomposition;
3.    neutralization temperature: +800?C to +1200?C;
4.    performance:
?    vapour capacity: 70 to 200 m3/h,
?    water solution capacity: 50 to 500 l/h;
5.    inlet pressure: up to 2 bars;
6.    automatic control system;
7.    overall dimensions shall allow for mounting the unit on a vehicle chassis.
medical waste incinerators manufacturers General Specifications
6mm plate steel sheel construction
11cm 1400 o C Refractory L iner
Temperature controlled Burners
Secondary combustion Burners
Interlock Switch on Load Doors
Separate Ash Door
One Second secondary Residence @ 1000 o C
400 ° C Silicone Based Paint Finish.
Alloy Temperature Sensor
Factory wired and tested
Capacity-20 kg / hr
Primary Chamber-1607 L
Hearth Area-1:36 sq. m
Secondary Chamber-694 L
Primary Burner (oil)-420,000 btu
Secondary Burner (oil)-900,000 btu
secondary Combustion-1/6 hp
Exhaust Stack-46cm x 6m
Electrical Service-220/50
Weight System-5.700 kg
Dimension “D”-152cm
Load Port Height- 60x 60 cm
Ash Port Height -36 x 36 cm

animal waste incinerator

secondary chamber

1000 degree

 

chimney

standard

 

shredder

separately

 

Autoclave or microwaves

separately

 

temperature monitor

attached outside of machine

 

operating

Fuel and electric

During the start and end incineration operations at the waste incineration plant the temperature shall be maintained

at 850 °C, while it shall be 1100 °C when incinerating dangerous waste containing halogenated organic substances with

content of chlorine or its compounds. The temperature shall be maintained at 1000 °C during incineration of medical

waste.

MUNICIPAL SOLID WASTE INCINERATORS

 

Municipal waste incinerator quantities and capacities shall be designed for 24-hour 7-day-a-week continuous operation.

 

Incinerators shall be capable of processing both wet and dry material and operating on either diesel fuel, JP-8 fuel,

 

or waste oil; see Plumbing for fuel storage system requirements. The following shall be provided as a minimum:

 

Reinforced concrete mounting foundations, feed or charging hoppers (or loaders), primary combustion chambers

 

with ash cleanout doors, secondary combustion chambers with ash cleanout doors, cyclone air filters (or separators),

Burner medical waste


Lately among customers informed us their goal to procure 1 system Gas Incinerator.medical waste burner to shed the wastes of university hospital in Egypt, the capacity asked for is 5 lots per day.the medium heater that takes advantage of both power as well as likewise oil.A SMALL PET CREMATORY WITH GAS


pet cremation equipment

Waste Incinerator Capacity

The waste incinerator units shall be designed to burn medical waste load of capacity 50 kg/hr with calorific values

ranging from 2,300 kJ/kg to 30,000 kJ/kg at a designed thermal rate of 1,440,000 kJ/hr.

 

Method of Waste Charging

Waste shall be fed into the primary chamber manually, that is by hand. Semi-automatic or automatic feeding systems are

not required.

 

Method of Burning

The primary and secondary burners shall be equipped with at least one fuel oil burner each. Waste shall be manually fed

into primary chamber and heated to required ignition temperature of at least 600 degree Celsius. A controlled amount of

air shall be admitted by combustion air blower to maintain the necessary reaction heat required for thermal degradation

of waste. Smoke, ashes, volatile gases, etc generated from the primary chamber shall be effectively and efficiently

ignited in the secondary chamber. Emission through the stack shall be within environmental standards.

 

Combustion Chambers

The internal lining for combustion chambers shall be made up of pre-determined thickness and high temperature stability

insulation, high strength firebricks and castible refractory. The temperature rating for refractory shall be at least

1,500 degree Celsius. The casing of the chamber shall be constructed from high grade mild steel plate. Lifting devices

such as eye bolts and lifting lugs shall be fitted as standard.

health care facility for melting contaminated materials along with chimicals


use in the health center for melting contaminated materials as well as chimicals, marginal Capacity 300 per hr. I will be marketing to my client?. Below is the information I was provided as well as definitely nothing else. The healthcare facility burner for usage in the professional waste as required by worldwide ecological administration. Minimum 300 Kg capacity/hr, Gas released, refractory lined, smokeshaft along with tasting prot. Minimum temperature level of 1100 level Celsiu.the incinerator tool for shed 500kg per hr. work concerning shed clinical waste of the hospitals.Just want to price of you different kinds of Medical Trash Incinerators.need all info on 300 kg per hr system. availability. practical expenses making use of diesel (numerous other). the waste is Human Cells. And also we have 10 kg each day; we require burner for scientific waste.Burn Capacity: 50kgs per hr (Ordinary capacity according to Medical Waste). please forward information regarding prices on each of you pet crematory models.Regarding Gas Incinerator, Please note that Fuel for the Incinerator
will be Gas. As gas is contribute our country.


Dual Burning Chamber Containerized Mobile Incinerator


Waste Burner Mounted in ISO 20′ ′ ′ ′ or 40 ′ Container before leave Factory. Normal Waste Burning Price from 10kgs to 150kgs per human resources.

Double Combustion Chamber

The incinerator format with primary burning chamber, added burning chamber( post burning) as well as dry scrubber optional. This style will lower black smoke, dropped totally as well as Environmentally Friendly.

Free Installation

The incinerator positioned currently in the container, total with gas system, electrical system and also the control circumstance repaired already. Take care of smokeshaft and also link electrical will certainly wait for operation.

Mobile Incinerator

Waste Heater Placed in ISO 20′ ′ ′ ′ or 40 ′ Container. It’s portable with car to anywhere or emergency situation demand.

Containerized Incinerator

Cost: upto 150kgs per hr

Containerized Incinerator: we shipment incinerator as well as likewise container to clients, no demand to construct incineration residence.

Double Combustion Chamber

Combustion Chamber: upto 1500Liters

Key burning for waste feeding as well as burning and also added burning to melt smoke only.

Incinerator Moveable by truck

Amount weight: 4Ton to 9Ton

Mobile function to anywhere or option to customer at their area website.


medical waste incinerator

medical waste incinerator: medical waste and general waste
Capacity to burn waste: 400 — 500 kg/hr
Fuel: Diesel
Fuel Consumption: 10 litres/hr maximum
Incineration temperature: 950 – 1300 °c
Casing: thick (min 5 mm) Stainless steel casing and fully
insulated to withstand sea humidity
Voltage: 220/240 V or 380/415V
Frequency: 50 Hz
Feeding: automatic
Ash 1 leftovers removal: Automatic
Fuel gas filtration system: Yes
Warranty: 12 months
Staff training: Operator & Maintenance staff
Operation and service manuals: 3 sets each
Especifica??es Gerais     6 mm plate steel sheel construction
11cm 1400°C refractory Liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000°C
400°C silicone Based finish paint
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1.36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service     220/50
System weight    5,700kg
Dimension “D”    152cm
Doad port height e    60x60cm
Ash port height e    36x36cm
General Specifications    6mm plate steel sheel construction
11cm 1400 ° C refractory liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000 ° C
400 ° C silicone based paint finish
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1:36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000 btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service    220/50
System weight    5.700 kg
Dimension “D”    152cm
Doad port height and    60x60cm
Ash port height and    36x36cm
medical, hospital, veterinary and industrial wastes by medical waste incinerator Process.
So, we’re interested with your Incinerator plants, and we’d like to get quotation and key features description of different capacities of your Incinerator plants, concerning: small models (5 – 25 kg/hr); medium models (25-50 kg/hr) and big models (50-100 kg/hr) and plus.

Environmental Protection Solutions


Incinerator

System Solutions for Medical Waste Environmental, consisting of Waste Incineration, Smoke Discharge Treatment, High-temperature Sterilization, Waste Crusher, Needle Destroyer, Medical Waste Plan and Containerized Mobile Incinerators.


incinerator 500kg per

Composition of the refractory lining:

* Insulation:

– Operating temperature:                1000 ° C max

– Nature:                                   Calcium Silicate

– Thickness:                              80 mm

* Refractory:

– Operating temperature:                1650 ° C max

– Nature:                                   Refractory bricks with 42 alumina

– Thickness:                              110mm

 

Burner combustion:

 

– The combustion chamber is equipped with a burner to line to ensure correct temperature for the total destruction of

waste combustion;

– Automatic monobloc burner and flame plunge equipped with an electronic ignition system and permanent ventilation.

Air fan:

– A primary air and secondary air fan provides the necessary oxygen delivery

– There is a motor operated valve that controls the flow according to the combustion.

– The pressure of the fan is 500 mm CE to pierce the mass of waste during combustion.

The Medical Waste Disposal Incinerator units shall be of Dual or Multiple Chamber type that thermally degrades

combustible medical wastes of varying heat content using a two-stage or multiple stages combustion processes. That is

first stage of thermal waste degradation in the primary chamber and second stage of smoke burning (flue gas treatment)

in the secondary chamber. The waste burning process per cycle shall be fully automatic from start to finish. The waste

incinerator unit shall consist of a primary chamber, secondary chamber, stack, combustion air blower, burners and

controls as the main components.