Top Feeding Door Solid Waste Incinerators HICLOVER

HICLOVER Top Feeding Door Waste Incinerators

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke




parts of an incinerator
physical method of disposing hazardous chemical waste
portable incinerators types
proper ways of waste disposal in the community
questionnaire to ask about incinerators for collection of data

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-08-07

High Temperature Incineration Process HICLOVER YD30

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Model YD-30 
Burning Rate  average 30 kgs/hour
Feed Capacity average 40 kgs
Paimary Combustion Chamber 200 Liters
Secondary Combustion Chamber 100 Liters
Mix Combustion Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.59Kw
Fuel Type Diesel Oil
Burner Italy Original
Oil Consumption (Diesel Oil) average 13.3 kg/hour
Gas Consumption (Natural Gas) ***
Internal Dimensions 80 x 50 x 50cm (paimary chamber)
External Dimensions 125 x 90 x 180cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 60 Liters
Door Opening 40 x 40cm
Chimney Length 1.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 1000 kgs




what is incineration
what is the cost of building incenerator in uganda
3d drawing of incinerator

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-07-28

Integrated Solid Waste Management System medical waste incinerator

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Capacity: Average 300 kgs per hour


Model

YD300

Picture

 

Burning Rate

Average 300 kgs/hour

Feed Capacity

Average 500 kgs/feeding

Primary Combustion Chamber

2400 Liters

Secondary Combustion Chamber

1200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Wet Scrubber System(3 Section Type)

Feed Mode

Manual

Voltage

380V

Power

12.0 Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 33kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

220 x 110 x 100cm (primary chamber)

External Dimensions

260 x 220 x 420cm (without chimney/wet scrubber)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

500 Liters

Door Opening

90 x 110cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

14000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800–1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal



Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy. 

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-07-27

Medical Waste Incinerators for Clinics and Small Hospitals

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Item

Serie No.

Part Name

Packing List

1#

Incinerator Mainbody

 

2#

Oil Tank(Deposit)

 

3#

Oil Tank(Daily)

 

4#

Chimney(Vertical,High Temperature)

 

5#

Chimney(Horizontal,High Temperature)

 

6#

Wet Scrubber

 

7#

Chimney(S shape)

 

8#

Chimney(Below)

 

9#

Chimney(Top)

Hospital Incinerators for Medical Waste Destruction

SN

 Item

Specification

1

Model

TS100

2

Burning Rate

Ave.50-100Kgs/Hour

3

Feeding Capacity

Ave.200Kgs/Feeding

4

Primary Chamber

1000 Liters

5

Secondary Chamber

540 Liters

6

Chimney

Yes

7

Wet Scrubber

Yes

8

Wet Scrubber Parameter

Dia. 100cm Hight 2500cm

9

Feeding Model

Manual

10

Power

380V 3P 50Hz

11

Power

6.0 Kw

12

Fuel Type

Diesel Oil

13

Burner

Italy

14

Oil Consumption (Diesel Oil)

Average 20.4 Kgs/Hour

15

Internal Dimensions Primary Chamber

120 x 100 x 90 cm

16

External Dimensions (Main Body)

270 x 190 x 170cm

17

Temperature Monitor

Yes

18

Oil Tank (Daily)

1.8M3

19

Oil Tank(Deposit) Parameter

10M3, Dia. 200cm Length 3500cm

20

Feeding Door

80 x 60cm

21

Chimney

6.0 M

22

Chimney Material

S.Steel

23

Weight

Ave.8500Kgs

24

1st. Chamber Temperature

800–1000

25

2nd. Chamber Temperature

1000-1200

26

Residency Time

2Sec.


 

2020-07-27

Small Medical Waste Incinerator 2 combustion chambers with scrubber

Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste

On-Site Incineration Solution‎

Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, 
and medical research facilities. These wastes include both infectious (“red bag”) 
medical wastes as well as non-infectious, general housekeeping wastes.

Items/Model

TS30(PLC)

Picture

 

Burn Rate

Average 20-30 kg/hour

Feed Capacity

Average 60kg per feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

Average 13.3

Gas Consumption (N.G, m3n/Hour)

Average 16

Gas Consumption (L.P.G, m3n/Hour)

Average 11.7

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

100L or More(Optional)

Feed Door

55x50cm

Chimney

5Meter or More(Optional)

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

4000kg

External Dimensions

175x120x140cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-27