HICLOVER Top Openning Door Waste Incinerators

Top Openning Door Waste Incinerators

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-09-02

HICLOVER Top Feeding Door Waste Incinerators

HICLOVER Top Feeding Door Waste Incinerators

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-08-07

Medical Waste Incinerator for covid19 waste 100-150-300-500kgs per hour

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

● Double Combustion Chambers
All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. 
● Containerized Mobile Incinerators
The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck. 
● Family Pets Dog&Cat Cremation
Special design with movable platform, combustion chamber material and custom made for pets crematory business. 
● Installation and Commissioning
Clover’s engineers install,train for most of the region and free-cost train in our factory. 


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Smoke Wet Scrubbers

Optional Optional Optional Optional

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


hospital incinerator ash
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-07-28

Medical Waste Incineration Model TS20(PLC) Wet Scrubber (Water Spary tower)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model

TS20(PLC)

Picture

 

Principle

Medical Waste Incineration 

Burn Rate

Average 20 kg/hour

Feed Capacity

Average 40kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

210L

Internal Dimensions

65x65x50cm

Secondary Chamber

110L

Smoke Filter

Wet Scrubber (Water Spary tower)

Feed Mode

Manual

Voltage

380V

Power

5Kw

Oil Consumption (kg/hour)

7.8–16.3

Gas Consumption (m3/hour)

8–15.7

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

45x40cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

4000kg

External Dimensions

160x110x130cm(Incinerator)





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-07-28

HICLOVER Waste Incinerator 10-500kgs/Hr.Double Combustion Chambers

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

General Waste Incinerator

For MSW

Mobile Incinerator(Optional)

Small-Middle scale, mobile function by

1. )Wheel

2.)DC-Power Trolley

3.)Trailer

4.)Containerized

Wet Scrubber for Smoke Filter(Optional)

1. ) 1 Section Wet Scrubber

2.)3 Sections Wet Scrubber

1 Section Wet Scrubber

S.S304 Cooling Spray tower

3 Sections Wet Scrubber

1.)S.S304 Cooling Spray tower

2.)S.S304 Dust Scrubber

3.) S.S304 Fog and Water Separator

Feeding Door

1.) Front/Side Manual Loading

2.) Top Feeding Door(Optional)

3.) Auto. Feeding Door(Optional)

3rd Combustion Chamber(Optional)

 

Stainless Steel Main Body(Optional)

S.S201 or S.S304

Control Model

1.) Electric control box(Semi-automatic)

2.) PLC Auto.control box(Automatic)

 

Light Weight Upgrade(Optional)

 

W2E(Waste to Energy)(Optional)

Hot Water(Non-drinking water)

Fuel Burner

Italy Baltur Brand

4.) Both D.O and N.G/LPG(not 2in1 burner, exchange burner type)

Temperature Thermocouple

1.) K Type,Stainless Steel 1300(Standard)

2.) K Type,Corundum 1300(Optional)

3.) S Type,Platinum Rhodium 1600(Optional)

Control Case Material

1.) Steel (Standard)

2.) Stailess Steel(Optional)

 

Chimney/Stack

1.) Stailess Steel (Standard)

2.) Steel(Optional)

3.)Length(Optional)

4.)Thickness(Optional)



Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Feed Door

80x60cm

80x60cm

 

 

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-27

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste.



HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-21

Smallest Waste Incinerator for PPE waste face mask glove waste

Smallest Waste Incinerator for PPE waste face mask glove waste
Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney
ave 10kgs per hour, 100kgs per day(10hr/day working)

Equipment Technical Specifications

Model

YD-10

Picture

 

Feed Capacity

Average 20 kgs per feeding

Burning Rate

Average 10 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Power

0.5Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

Ave. 4.2 Kgs/Hour

External Dimensions

Dia.100 x 130cm (mainbody)

Internal Dimensions

Dia.50 x 80cm

Waste combustion chamber

200Liters

Oil Tank Capacity

100 Liters

Door Opening

35 x 35cm

Chimney

1.5M

Gross Weight

Ave.400kgs

Chamber Material

Refractory Concrete&Ceramic Fiber 

Max. Heat Value

42,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

14000C

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-17

Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower

Model

YD-150

Burning Rate

Average 150 kgs/hour

Feed Capacity

Average 300 kgs/feeding

Primary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.03Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

17–36 kg/hour

Gas Consumption (Natural Gas)

11–36.7 m3/hour

Internal Dimensions

150 x 100 x 96cm (primary chamber)

External Dimensions

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

7500 kgs

before start the 2nd burner, full close all air valve on the 1st chamber. other operation keep same. 
reason: at the first 10-20 min burnning the plactic waste, deflagration combustion in the chamber. 
after 10-20 min, gradually increase air injection by air valve on the 1st chamber.
meanwhile, proposal 20-30 min burnning of the 1st chamber, stop the 1st burner(stop fire only, the fan inside the burner 
still working), let the plastic burn itself(Spontaneous combustion) to save diesel oil.
a small waste to energy project to turn municipal solid waste 

Model

YD-150

Main Product List

Primary Combustion Chamber

 

Secondary Combustion Chamber

 

Mix-Combustion Chamber

 

Smoke Filter Chamber(Dry Scrubber)

 

Incinerator Control Case(PLC Auto.Type)

 

Chimney:10.0Meters

*(upgrade to Stainless Steel, free cost)

 

Italy oil/gas burner: 02 sets

 

Oil Tank (if oil fuel): 300Liters

 

Optional Part:

Stainless Steel Wet scrubber(Cooling Spray tower)

 

into electricity. The project is to cater for a local council with a population of around 60,000 people and will serve as a 
pilot project. If project is successful than other such plants will be installed in other towns and villages. The villages 
will all cater for the MSW in their locality instead of a central large incineration plant to cate for the whole county.for a 7 ton per 
hour plant on turn-key basis with your best price and delivery including full technical specifications, literature, drawings 
and best export price.
Provided you can offer a good solution there is a chance of selling many more such plants for the local councils of the same 
country, so this is an excellent chance for you to join forces with our company for market penetration with your products in 
Europe.
1. TS100 model with dry scrubber system
2. YD150 with a wet scrubber system

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-14

Incinerator burn medical and bio waste

Incinerator burn medical and bio waste

Items/Model

TS100(PLC)

Picture

 

Principle

Medical  Waste Incineration Treatment

Burn Rate

Average 100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V/380V

Power

0.7Kw

Oil Consumption (kg/hour)

average 20.4

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-14

Incineration plant machine of 150kg/hr on LPG

Incineration plant machine of 150kg/hr On Lpg

Items/Model

TS150(PLC)

Picture

 

Principle

Medical Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1500L

Internal Dimensions

150x100x100cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.9Kw

Oil Consumption (kg/hour)

Average 24.2(D.O)

Gas Consumption (m3n/hour)

Average 21.3(LPG)

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x190cm



HICLOVER – Medical Environmental, WWW.HICLOVER.COMWaste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com 
Nanjing Clover Medical Technology Co.,Ltd.



 